11
TROUBLESHOOTING
The following items are the most common tool symptoms if problems should occur. For symptoms
or remedies not shown, contact your Signode service representative for additional information and
details. The following tool symptoms are shown in this manual:
#1 SYMPTOM: Tool leaking air (
Trigger in OFF position & tool at rest).
#2 SYMPTOM:
Tool leaking air (Trigger in ON position while sealing).
#1 SYMPTOM: Tool leaking air (
Trigger in OFF position and tool at rest). **
CAUSE
REMEDY
1.
Air leakage between mounting plate and
cylinder.
2.
Air leakage at bottom of valve assembly
by trigger.
3.
Air leakage at top of valve assembly by
exhaust holes of valve plug.
1. Replace mounting plate o-ring (Key 18).
2. Adjust valve plug as described in this
manual. Disassemble, inspect, and repair
valve assembly.
3. Adjust valve plug as described in this
manual. Replace piston o-ring (Key 19).
Disassemble, inspect, and repair valve
assembly.
#2 SYMPTOM:
Tool leaking air (Trigger in ON position while sealing).
**
CAUSE
REMEDY
1.
Air leakage at bottom of valve assembly
by trigger.
2.
Air leaking by exhaust holes at top of
valve assembly or around valve plug.
1. Disassemble, inspect, and repair valve
assembly. Replace piston o-ring (Key 19).
2. Disassemble, inspect, and repair valve
stem.
** Please note that there will be an initial rush of air from around the trigger when it is
pressed to the ON or sealing position.