SIGNIFY Hadco V671 Series Скачать руководство пользователя страница 2

LAMP REPLACEMENT
NOTE: It is a good idea to clean the fixture each time you relamp.  Avoid using harsh solvents

      or abrasives.

STEP   1: Release spring clip that secures the hinged roof.  Open roof [see Fig. 1 on page 1].

STEP   2: Remove the old lamp and dispose of it in accordance with local codes and regulations.

STEP   3: Install a new lamp, referring to the lamp label next to the socket to ensure using the

          correct type.

STEP   4: Clean installed lamp of all dirt and body oils.

STEP   5: Close the roof and secure.

          * Verify that the spring clip snaps back into place.

INSTALLATION
WARNING - The power MUST be turned off prior to proceeding.  Read these instructions carefully.

      If any problems are encountered that are not covered in these instructions, contact Hadco

      for assistance.
STEP 1: WIRING

        1.1 Use wire nuts to connect incoming power supply wires to the fixture supply wires.

        1.2 Provide a suitable strain relief for wiring.

STEP 2: MOUNTING

        2.1 Mount the housing onto a 3" diameter post shaft or tenon.

        2.2 Use the post fitter's 5/16-18 set screws, supplied in the fixture, to secure the

            housing to the post shaft or tenon.

STEP 3: OPEN ROOF

        3.1 Release the spring clip that secures the roof [see FIG. 1 on page 1].

        3.2 Swing roof open to access lamp compartment.

STEP 4: LAMPING

        4.1 Install the correct lamp based upon the lamp label next to the socket.

        4.2 Clean installed lamp of all dirt and body oils.

        4.3 Type III House-side Shield option ONLY. (Available for refractor panels only.)

            * Rotate the reflector shield assembly around the socket to the correct orientation.

                 ** Note: the reflector is the house side.

STEP 5: Close roof and secure with spring clip.

        * Verify that spring clip snaps back into place and secures roof.

STEP 6: Connect power and test the fixture for proper operation.

STEP 7: After the installation is complete, deliver this manual to the owner.

TOOLS REQUIRED FOR INSTALLATION
1. 5/32" Allen Wrench

2. Screw Driver [#8-10, slotted type]

3. Screw Driver [phillips type]

4. Wire connectors for appropriate wire

TWIST-LOCK RECEPTACLE INSTALLATION / REPLACEMENT
NOTE: DECORATIVE VENT CAP is keyed to MOUNTING PLATE to ensure mounting in one direction

      so that PHOTO CELL is properly oriented with PHOTO CELL LENSE.

STEP  1. Pull DECORATIVE VENT CAP from ROOF.

STEP  2. Ensure TWIST-LOCK RECEPTACLE is facing northward, if it is not facing northward the

         following two adjustments could be made;

         2.1 TWIST-LOCK RECEPACLE can be repositioned in 90~ increments by removing

             and reinstalling the two MOUNTING SCREWS. Ensure MOUNTING PLATE & TWIST-LOCK

             RECEPTACLE are rotated in unison.

         2.2 Fixture could also be rotated on top of pole.

STEP  3. Install PHOTO CELL into TWIST-LOCK RECEPTACLE.

STEP  4. Reposition DECORATIVE VENT CAP and MOUNTING CLIPS into slots of the MOUNTING PLATE.

         * Varify that the PHOTO CELL LENS is at the same location as the PHOTO CELL EYE.

STEP  5. Press DECORATIVE VENT CAP firmly into place.

page 2 of 3

32001402, revision F

Отзывы: