TOOLS REQUIRED
FOR INSTALLATION
1. Flat head screw driver - to open or close lens door.
2. Phillips head screw driver - to remove or re-install the reflector assembly and ballast assembly.
3. 5/16" Allen wrench - to assemble (2) piece clamp collar
FOR RELAMPING:
1. Flat head screw driver - To attain access to the lamp by opening the lens door.
INSTALLATION (CF5T)
WARNING - The power MUST be turned off prior to proceeding. Read these instructions carefully. If any
problems are encountered that are not covered in these instructions, contact Hadco for assistance.
STEP 1: The fixture is designed to hang from the Universal Fixture Adapter.
- To hang the fixture, first connect the power supply quick-connect on the fixture
to the quick-connect on the arm.
- Then hang the fixture per the instructions supplied with your Adapter.
* Be sure the fixture is straight and securely attached before proceeding.
STEP 2: OPEN LENS DOOR
- To open the lens door, loosen the (2) 1/4-turn studs. This allows the door to swing
open. A safety cable will prevent it from falling, should it come out of the hinge.
STEP 3: INSTALL LAMP
- Install the correct lamp based upon the lamp label next to the socket.
STEP 4: CLOSE LENS DOOR
- Close the lens door and tighten the (2) 1/4-turn studs.
STEP 5: TYPE 2, 3, or 4 OPTICS (only)
- Carefully loosen the (2) Adapter screws just enough to rotate the fixture.
- Rotate the fixture to the desired orientation.
- Then retighten the screws to lock the fixture in that position.
STEP 6: Connect the power, and test the fixture for proper operation.
STEP 7: After the installation is complet, deliver this instruction manual to the owner.
TO REPLACE LAMP
STEP 1: It is a good idea to clean the fixture each time you relamp. Avoid using harsh
solvents or abrasives while cleaning fixture.
STEP 2: Open the lens door by loosening the (2) 1/4-turn studs.
STEP 3: Remove the old lamp and dispose of it in a responsible manner.
STEP 4: Install a new lamp, referring to the lamp label next to the socket to ensure
the correct type.
STEP 5: Close the lens door and tighten the (2) 1/4-turn studs.
DISCLAIMER
While we believe these instructions to be accurate at the time of publication, Hadco reserves
the right to make changes to this fixture and/or components. The contractor should follow local
and national electrical codes where required. For any further information please contact Hadco
customer service.
page 2 of 2
32001043, revision F