Emergency Voice
Communication System
Note
: Some Operator functions require a security PIN code entering. This code can only be changed by a system
engineer. Therefore, ensure that the security PIN code is held by a responsible person and NOT lost.
The default code is
2222
but keep a record of the code in the boxes, right.
With the
unit’s handset on-hook, press
FUNCTION
(or
F
) button. The
User Opts
menu is displayed.
Note
: The
User Opts
menu for a networked unit is different to that on a non-networked unit (see examples below):
15.1 Clear recent calls
To make it easier to call back to outstations, the system keeps a record of incoming calls for up to 24 hours after the
system was last used. To manually clear this list press
FUNCTION
(or
F
) button and select
Clr Rcnt Calls
option.
Note
: The system can be set up to automatically clear the recent call list after a set time period (between 6 to 24
hours). This is set up by a system engineer.
15.2 System reset
This option provides a clean restart to the system and is used for an emergency recovery in case the system gets
into an unforeseen condition, e.g. persistent faults not clearing.
1. At the master wall control unit, press
FUNCTION
button and select
Reset
System
option.
2. Enter the security PIN code using the keypad.
A full system reset is carried out.
15.3 Firmware version
If you need to find out which version of firmware is installed on the EVCS press
FUNCTION
(or
F
) button and select the
About
…
option.
The firmware version is displayed and also the name of the control unit (typical display
shown right).
15.4 Alt. masters
This function is only available on a networked system and gives control to a repeater unit from the current master unit
when no calls are present on the EVCS. See section 16.3.
15.5 Take control
This function is only available on a networked system and
allows
a repeater unit to
take control from the current master
unit when no calls are present on the EVCS. See section 16.2.
U s e r O p t s
>
C l r R c n t C a l l s
R e s e t S y s t e m
A b o u t . . .
E V C S
v 5 . 6 . 0
W all Unit 1
U s e r O p t s
>
C l r R c n t C a l l s
A l t . M a s t e r s
R e s e t S y s t e m
A b o u t . . .
U s e r O p t s
>
T a k e C o n t r o l
A b o u t . . .
Non-networked
MCU Wall Unit
Networked ‘master’
MCU Wall Unit
Networked
‘repeater’
MCU Wall Unit
E n t e r
P I N
.......
.......
.......
.......
Networked ‘repeater’
Desk Control Unit
> C l r R c n t C a l l s
T a k e C o n t r o l
A b o u t …