Operator Instructions

 

SigTEL

 

Approved Document No. DAU0000092 Rev 4 

Page 12 of 16 

Emergency Voice 
Communication System 

 

Note

: Some Operator functions require a security PIN code entering. This code can only be changed by a system 

engineer. Therefore, ensure that the security PIN code is held by a responsible person and NOT lost. 

The default code is 

2222

 but keep a record of the code in the boxes, right. 

 

 

 

With the 

unit’s handset on-hook, press 

FUNCTION

 (or 

F

) button. The 

User Opts

 menu is displayed. 

Note

: The 

User Opts

 menu for a networked unit is different to that on a non-networked unit (see examples below): 

 

 

 

 

15.1  Clear recent calls 

To make it easier to call back to outstations, the system keeps a record of incoming calls for up to 24 hours after the 
system was last used. To manually clear this list press 

FUNCTION

 (or 

F

) button and select 

Clr Rcnt Calls

 option. 

Note

: The system can be set up to automatically clear the recent call list after a set time period (between 6 to 24 

hours). This is set up by a system engineer. 

 

15.2  System reset 

This option provides a clean restart to the system and is used for an emergency recovery in case the system gets 
into an unforeseen condition, e.g. persistent faults not clearing. 

 

1.  At  the  master  wall  control  unit,  press 

FUNCTION

  button  and  select 

Reset 

System

 option. 

 

2.  Enter the security PIN code using the keypad. 

A full system reset is carried out. 

 

 

15.3  Firmware version 

If  you  need  to  find  out  which  version  of  firmware  is  installed  on  the  EVCS  press 

FUNCTION

 (or 

F

) button and select the 

About

 option. 

The firmware version is displayed and also the name of the control unit (typical display 
shown right). 

 

15.4  Alt. masters 

This function is only available on a networked system and gives control to a repeater unit from the current master unit 
when no calls are present on the EVCS. See section 16.3. 

 

15.5  Take control 

This function is only available on a networked system and

 

allows

 

a repeater unit to

 

take control from the current master 

unit when no calls are present on the EVCS. See section 16.2. 

U s e r   O p t s  

 

>

C l r   R c n t   C a l l s  

    R e s e t   S y s t e m  
    A b o u t . . .  

E V C S  

v  5 . 6 . 0 

 

W all Unit  1  

U s e r   O p t s  

 

>

C l r   R c n t   C a l l s  

    A l t .   M a s t e r s  
    R e s e t   S y s t e m  
    A b o u t . . .  

 

U s e r   O p t s  

 

>

T a k e   C o n t r o l  

    A b o u t . . .  

Non-networked 

MCU Wall Unit 

Networked ‘master’ 

MCU Wall Unit 

Networked 

‘repeater’ 

MCU Wall Unit 

E n t e r  

P I N  

 

 

 

....... 

 

....... 

 

....... 

 

....... 

 

Networked ‘repeater’ 

Desk Control Unit 

 

> C l r   R c n t   C a l l s  

T a k e   C o n t r o l  

A b o u t …  

Содержание SigTEL Compact

Страница 1: ...TEL Compact Emergency Voice Communication System EVCS Operator Instructions Approved Document No DAU0000092 Rev 4 Wall Control Unit with handset Wall Control Unit no handset Desk Control Unit with handset ...

Страница 2: ...OL UNITS ARE WORKING 8 11 HANDLING CALLS AT THE DESK CONTROL UNIT 8 11 1 TO ANSWER A CALL 8 11 2 TO END A CALL 8 11 3 ENDING ONE CALL AND ANSWERING ANOTHER 9 11 4 TO CALL AN EXTENSION 9 11 5 MANUAL ANSWER MODE I E AUTO ANSWER MODE DISABLED 9 12 TYPES OF OUTSTATION 10 13 MAKING A CALL FROM AN OUTSTATION 10 14 ANSWERING A CALL AT AN OUTSTATION 10 15 ADDITIONAL OPERATOR FUNCTIONS 11 15 1 CLEAR RECENT...

Страница 3: ...of the site is required by law The Regulatory Reform Fire Safety Order 2005 to appoint a responsible person to ensure the EVCS and other safety systems remains operational 3 System Overview The EVCS provides reliable two way communication between one or more permanently manned control rooms and key points on the site in a fire emergency The EVCS comprises of fire telephone and or disabled refuge s...

Страница 4: ...ower supply or back up batteries General Fault Amber There is a local or remote fault on the EVCS The display will show more information Power Green Power Mains or battery is present 5 2 Wall control unit display The display shows call status system information fault information and uses the following graphic symbols Display conventions Standard non active displays are shown normally e g Extension...

Страница 5: ...menus Scroll Down CALL ACCEPT Make Accept Calls Select Menus When the wall control unit s handset is off hook press this button to either make an outgoing call to an extension or accept an incoming call from an extension Also selects menu options END End a Call ESC to previous menu Lamp test When the wall control unit s handset is off hook press this button to disconnect the caller When the wall c...

Страница 6: ...are lit and the display shows the current system status see typical displays below Note The wall control unit displays are different for a networked system and a non networked system 9 Handling Calls at the Wall Control Unit Section 9 1 to 9 4 applies to both a non networked wall control unit and the current master wall control unit on a networked system It is assumed that auto answer mode is enab...

Страница 7: ...r the recent calls list see section 15 1 9 5 Manual answer mode i e auto answer mode disabled By default auto answer mode is enabled which means a wall control unit automatically answers an incoming call when its handset is picked up This provides a simple method of answering calls but provides less control for an Operator when there are multiple calls on the system In manual answer mode the Opera...

Страница 8: ...ion is calling or you are connected to that extension 11 Handling Calls at the Desk Control Unit Sections 11 1 to 11 4 applies to both a non networked desk control unit and current master desk control unit on a networked system It is assumed that auto answer mode is enabled this is the mode most likely to be setup for the system Additional call handling facilities are available for a networked sys...

Страница 9: ...ise the full directory is shown You can toggle between History list and full directory by pressing D DIRECTORY button Press and to highlight the extension you want to talk to then press CALL ACCEPT to call To clear the recent calls list see section 15 1 11 5 Manual answer mode i e auto answer mode disabled To answer a call When there is an incoming call pick up the handset and press CALL ACCEPT bu...

Страница 10: ... At Type A outstations pick up the handset and a double beep beep ringing tone sounds in the earpiece At Type B outstations press the Push to Call or Answer button and a double beep beep ringing tone sounds in the loudspeaker and the Call in Progress indicator is lit steady At the wall control unit or desk control unit the ringer sounds and the Operator can choose to answer If the Operator is talk...

Страница 11: ...AU0000092 Rev 4 Page 11 of 16 Emergency Voice Communication System 15 Additional Operator Functions Additional Operator options shown below are available by pressing FUNCTION button at a wall control unit or F button at a desk control unit when the handset is on hook ...

Страница 12: ...se the system gets into an unforeseen condition e g persistent faults not clearing 1 At the master wall control unit press FUNCTION button and select Reset System option 2 Enter the security PIN code using the keypad A full system reset is carried out 15 3 Firmware version If you need to find out which version of firmware is installed on the EVCS press FUNCTION or F button and select the About opt...

Страница 13: ...its display the message shown right 2 At any repeater unit pick up its handset and enter the requested security PIN code using the keypad 3 The repeater unit takes control of the system becomes the current master unit and answers the call The displays at each unit on the network confirm their network status 16 2 To take control from the master unit at a repeater unit when no outstations calling in...

Страница 14: ...nswered and ended at a control unit but the handset at the outstation has been left off hook for longer than 2 minutes Jammed button detection at Type B outstations Scenario A call has been made from a Type B outstation the call has been answered and ended at a control unit but the button at the outstation has pressed jammed for longer than 2 minutes For the two scenarios above after the 2 minutes...

Страница 15: ...all control unit s display toilet alarms are denoted by the graphic symbol wc which is reversed wc when active This symbol will never appear in the same list as outstations and pressing the DIRECTORY button will not show toilet alarms because you cannot call them Similarly toilet alarms will not appear in the Recent Calls list When a toilet alarm is activated its name is displayed at the control u...

Страница 16: ...an be installed The MCU has a handset mounted on its front panel Part number ECU 16 ECU 8 or ECU 4 network master a wall or desk control unit on a network that currently has control over the EVCS i e the master Any other control unit on a network acts as a repeater The current master unit can give control to any repeater unit by entering a security PIN code There can only be one master unit at any...

Отзывы: