Signcomplex AL-100-AW/HV-30K-ZYY Скачать руководство пользователя страница 2

Signcomplex

We bring innovation and give inspiration

P2

Tel:+86-755-27608650              Fax:+86-755-27608651              [email protected]
Yijia Industrial Park, Fuqian Road, Guanlan Town, Baoan, Shenzhen, Guangdong, China

www.signcomplex.com

AC100-277V

    50/60Hz

SMD

2835

100

AL-100-AW/HV-57K-ZYY

AL-100-AW/HV-50K-ZYY

AL-100-AW/HV-40K-ZYY

AL-100-AW/HV-35K-ZYY

AL-100-AW/HV-30K-ZYY

AL-150-AW/HV-57K-ZYY

AL-150-AW/HV-50K-ZYY

AL-150-AW/HV-40K-ZYY

AL-150-AW/HV-35K-ZYY

AL-150-AW/HV-30K-ZYY

AL-200-AW/HV-57K-ZYY

AL-200-AW/HV-50K-ZYY

AL-200-AW/HV-40K-ZYY

AL-200-AW/HV-35K-ZYY

AL-200-AW/HV-30K-ZYY

AL-240-AW/HV-57K-ZYY

AL-240-AW/HV-50K-ZYY

AL-240-AW/HV-40K-ZYY

AL-240-AW/HV-35K-ZYY

AL-240-AW/HV-30K-ZYY

AL-300-AW/HV-57K-ZYY

AL-300-AW/HV-50K-ZYY

AL-300-AW/HV-40K-ZYY

AL-300-AW/HV-35K-ZYY

AL-300-AW/HV-30K-ZYY

13000

13000

13000

12300

12000

20040

20040

20500

19500

18900

25300

25300

26300

24400

23800

31700

31700

33000

31000

30240

37800

37800

39400

36800

36000

Lumen(lm)

(

±

10%)

  Beam 
(angle

°

Power(w)

(

±

10%)

Voltage,

Frequency

Model

 LED Type

Color

5700K

5000K 

4000K

3500K

3000K

5700K 

5000K 

4000K

3500K

3000K

5700K 

5000K

4000K

3500K 

3000K

5700K 

5000K

4000K

3500K 

3000K

5700K 

5000K

4000K

3500K 

3000K

Specifications:

Type 

 Ⅳ

Type

Type 

>80

0.9

PF

CRI

Current

1.2A

AC100-277V

    50/60Hz

SMD

2835

150

Type 

 Ⅳ

Type

Type 

>80

0.9

1.8A

AC100-277V

    50/60Hz

SMD

2835

200

Type 

 Ⅳ

Type

Type 

>80

0.9

2.2A

AC100-277V

    50/60Hz

SMD

2835

240

Type 

 Ⅳ

Type

Type 

>80

0.9

2.7A

AC100-277V

    50/60Hz

SMD

2835

300

Type 

 Ⅳ

Type

Type 

>80

0.9

3.5A

Model: AL-XXX-AW/HV-XXK-ZYY

XXX-

AW/HV-

XXK-

ZYY

Family

Power

:

 100

       

 150

              200
              240
              300

AW

:

100

-

277V

HV

:

277

-

480V

Color 

:

 30K

             35K
             40K
             50K
             57K

D30:Type

D40:Type

D50:Type

S30:Photocell

 

Type

S40:Photocell

 

Type

S50:Photocell

 

Type

S31:Motion sensor

 

Type

S41:Motion sensor

 

Type

S51:Motion sensor

 

Type

 AL-

0-10V dimmable: 10%-100% brightness dimmable

Содержание AL-100-AW/HV-30K-ZYY

Страница 1: ... resistance 5 A variety of light distribution optional TypeIII Type IV Type V 6 one person can instal fixture thanks for the unique straight arm 7 Operating environment temperature 40 40 8 Corrosion resistance grade W 9 Colour Bronze Area lights can be used in parking lot plaza alley park farm gas station community roadway and other outdoor location Die casting structure shockproof strong corrosio...

Страница 2: ...0 20040 20040 20500 19500 18900 25300 25300 26300 24400 23800 31700 31700 33000 31000 30240 37800 37800 39400 36800 36000 Lumen lm 10 Beam angle Power w 10 Voltage Frequency Model LED Type Color 5700K 5000K 4000K 3500K 3000K 5700K 5000K 4000K 3500K 3000K 5700K 5000K 4000K 3500K 3000K 5700K 5000K 4000K 3500K 3000K 5700K 5000K 4000K 3500K 3000K Specifications Ⅲ Type Ⅳ Type Ⅴ Type 80 0 9 PF CRI Curre...

Страница 3: ...e may be As the case may be As the case may be Straight arm bracket D Round pole ADC12 Aluminum alloy ADC12 Aluminum alloy ADC12 Aluminum alloy Q235 Steel Intensity distribution diagram Type Ⅴ Type Ⅲ Type Ⅳ Area lights Series Area lights Series Area lights Series Area lights Series 0 30 60 90 120 150 180 150 120 90 60 30 0 3000 6000 9000 12000 15000 0 30 60 90 120 150 180 150 120 90 60 30 0 3000 6...

Страница 4: ...her than 100Lux 1minutes later the lamp will be off and disable motion sensor function 5 Above functions are defaults of our products if product functions and parameters need to be revised the remote controller RC 100 need to be purchased and the remote controller need to be bought separately 2 3 4 4 4 switch on Brief introduction of remote controller 15m The ShoeBox LED light with Motion Sensor a...

Страница 5: ...a www signcomplex com Photocell function Light sensing series when environment illumination is lower than 6Lux the lamp will switch on in 20 seconds when environment illumination is higher than 50Lux the lamp will switch off in 20 seconds Application Suitable for parking lot plaza roadway park farm gas station Tennis courts large commercial and retail venues community and other outdoor places ...

Страница 6: ...ion Unit mm inch Installation hole dimension Slip Fitter Straight arm bracket C Trunnion bracket 65 2 56 77 3 03 144 5 67 50 1 97 128 5 04 88 3 46 4 9 0 35 18 0 71 143 5 63 18 0 71 10 0 0 39 14 0 55 10 0 39 108 4 25 78 3 07 20 5 0 81 21 0 83 9 0 35 50 1 97 Straight arm bracket D 13 0 51 90 3 54 13 0 51 55 2 17 100 3 94 11 0 43 83 3 27 50 1 97 90 3 54 11 0 43 U Trunnion bracket 100W 150W 200W U Tru...

Страница 7: ...3 143 5 63 80 3 15 18 0 71 10 0 0 39 14 0 55 10 0 39 108 4 25 78 3 07 314 12 36 Slip Fitter Straight arm bracket C Trunnion bracket Straight arm bracket D 526 20 71 718 28 27 143 5 63 80 3 15 18 0 71 10 0 0 39 14 0 55 10 0 39 108 4 25 78 3 07 314 12 36 526 20 71 688 27 09 144 5 67 50 1 97 128 5 04 88 3 46 4 9 0 35 18 0 71 314 12 36 526 20 71 645 25 39 83 3 27 20 5 0 81 21 0 83 9 0 35 50 1 97 314 1...

Страница 8: ...o place Straight arm bracket C 100 150mm 3 94 5 91 inch square pole 2 Open pole Cap 3 Open lamp cover 1 Confirm installation location according to installation hole 3 Open pole Cap 1 Confirm installation location according to installation hole Photocell Series 2 Open pole Cap 1 Confirm installation location according to installation hole Motion Sensor series 4 Put all of the wire through lamp hole an...

Страница 9: ...dust lighting angle of lamp 90 90 5 Insert the Motion sensor into socket with correct holes then clockwise rotate it into place 6 Fix and adjust angle screw installation finish Motion Sensor series Trunnion bracket 5 Adust lighting angle of lamp 90 90 6 Fix and adjust angle screw installation finish 4 Adust lighting angle of lamp 90 90 5 Fix and adjust angle screw installation finish 3 Open lamp cove...

Страница 10: ...t of the angle tighten the xing bolts 4 Connect the power cord of the light with commercial power Waterproof sealing for the joint should be carried properly 1 bore holes on the installation surface according to installation hole position on the main bracket to install 2 3pcs M10 M12 expansion bolts 2 Install at washers spring washers and nuts to x and tight the min bracket and expansion bolts to ...

Страница 11: ...0W 5 2kg 6 2kg 680 375 155mm 1PCS carton 300W 7 1kg 8 6kg 795 390 195mm 1PCS carton 240W 6 6kg 8 1kg 795 390 195mm 1PCS carton 100W 3 9kg 4 8kg 580 375 155mm 1PCS carton Power Net weight Gross weight Packing dimension Packing qty 150W 5 3kg 6 3kg 680 375 155mm 1PCS carton 200W 5 4kg 6 4kg 680 375 155mm 1PCS carton 300W 7 5kg 9kg 795 390 195mm 1PCS carton 240W 6 7kg 8 2kg 795 390 195mm 1PCS carton ...

Страница 12: ... 4 If there is any damage to the power wire or shell of the product it should be taken as defective product and do not use it 5 Dangerous high voltage non professionals are not allowed to maintain the product 6 If external soft cable or soft wire of the light is damaged it should be replaced by manufacturer or service agent or personnel with similar qualification to avoid danger 7 Please pull the ...

Отзывы: