Chapter 7
| Flow Sampling Commands
– 188 –
This example shows how to modify the sFlow port number for an already
configured collector.
Console(config)#sflow owner stat_server1 timeout 100 port 35100
Console(config)#
sflow polling instance
This command enables an sFlow polling data source, for a specified interface,
that polls periodically based on a specified time interval. Use the
no
form to
remove the polling data source instance from the switch’s sFlow configuration.
Syntax
sflow polling
{
interface
interface
}
instance
instance-id
receiver
owner-name
polling-interval
seconds
no sflow polling
{
interface
interface
}
instance
instance-id
interface
- The source from which the samples will be taken at
specified intervals and sent to a collector.
ethernet
unit
/
port
unit
- Unit identifier. (Range: Always 1)
port
- Port number. (Range: 1-52)
instance-id
- An instance ID used to identify the sampling source.
(Range: 1)
owner-name -
The associated receiver, to which the samples will be
sent. (Range: 1-30 alphanumeric characters)
polling-interval
-
The time interval at which the sFlow process
adds counter values to the sample datagram. (Range: 0-10000000
seconds, 0 disables this feature)
Default Setting
No sFlow polling instance is configured.
Command Mode
Privileged Exec
Command Usage
This command enables a polling data source and configures the interval at
which counter values are added to the sample datagram.
Example
This example sets the polling interval to 10 seconds.
Console(config)#interface ethernet 1/9
Console(config-if)#sflow polling-interval 10
Console(config-if)#
Содержание SC30010
Страница 1: ...C 300 Series Gigabit Managed Switch CLI Reference Guide SOFTWARE RELEASE V1 1 10 171 www signamax com ...
Страница 2: ...CLI Reference Guide SC30010 C 300 48 Port Gigabit Managed Switch E122017 KS R01 ...
Страница 482: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 482 ...
Страница 670: ......