Signamax
™
065-7931 16-Port 10/100/1000BaseT/TX Web Smart Switch
54
4-2-2. Ports Configuration
Function name:
Ports Configuration
Function description:
Ports Configuration is applied to change the setting of each port. In this
configuration function, you can set/reset the following parameters, Mode and
Flow Control. All of them are described in detail below.
Parameter description:
Mode:
Set the speed and duplex of the port. If the media is 1Gbps fiber, there
are three modes to choose: Auto Speed, 1000 Full and Disable. If the
media is TP, the Speed/Duplex is comprised of the combination of speed
mode, 10/100/1000Mbps, and duplex mode, full duplex and half duplex.
The following table summarized the function the media supports.
Media type
NWay
Speed
Duplex
1000M TP
ON/OFF
10/100/1000M
Full for all, Half for 10/100
1000M Fiber
ON/OFF
1000M
Full
In Auto Speed mode, no default value. In Forced mode, default value
depends on your setting.
Flow Control:
There are two modes to choose in flow control, including Enable and
Disable. If flow control is set Enable, both parties can send PAUSE frame
to the transmitting device(s) if the receiving port is too busy to handle.
When it is set Disable, there will be no flow control in the port. It drops
the packet if too much to handle. Default: Enable
Fig. 4-4