Managed Ethernet Switch
User’s Manual 146
3.
Command Syntax:
snmp-server community get NAME
no snmp-server community get
NAME The get community name for SNMP.
4.
Example:
The following example specifies get community name (
name
) for SNMP:
switch_a(config)#snmp-server community get name
switch_a(config)#
Set Community Name:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
snmp-server community set
command to specify and
no
snmp-server community set
command to remove set community name for
SNMP.
3.
Command Syntax:
snmp-server community set NAME
no snmp-server community set
NAME The set community name for SNMP.
4.
Example:
The following example specifies set community name (
name
) for SNMP:
switch_a(config)#snmp-server community set name
switch_a(config)#
SNMP v3
SNMPv3 No-Auth:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Add a user using snmp v3 with read-only or read-write access mode and
without authentication. Use the no form of the command to delete this user.
3.
Command Syntax:
Содержание 065-7734
Страница 1: ...Signamax Connectivity Systems Managed Ethernet Switch Model 065 7734 U S E R S G U I D E ...
Страница 35: ...Managed Ethernet Switch User s Manual 34 ARP Table Click ARP Table to view ARP Table ...
Страница 40: ...Managed Ethernet Switch User s Manual 39 Reboot Reboot Click Reboot button to restart the switch ...
Страница 41: ...Managed Ethernet Switch User s Manual 40 Logout Logout Click Logout button to logout of the switch ...
Страница 53: ...Managed Ethernet Switch User s Manual 52 ...
Страница 58: ...Managed Ethernet Switch User s Manual 57 ...
Страница 59: ...Managed Ethernet Switch User s Manual 58 ...
Страница 63: ...Managed Ethernet Switch User s Manual 62 ...