59
SIGNAMAX LLC • www.signamax.eu
Port No:
Port number.
Port On:
Show whether the port is supplying the power to the PD or not.
AC Disconnect Port Off:
Port is turned off due to the AC Disconnect function.
DC Disconnect Port Off:
Port is turned off due to the DC Disconnect function.
Overload Port Off:
The switch will stop supplying the power to the port due to the power
required by the PD that is linked to the port on the switch excesses the
Class setting of the PD.
Short Circuit Port Off:
The switch will stop supplying the power to the port if it detects that the
PD linked to the port is short circuit.
Over Temp. Protection:
The port of the switch will be disabled due to fast transient rise in
temperature to 240
o
C or slow rise in temperature to 200
o
C.
Power Management Port Off:
Due to total power required by all PDs linked to the switch excesses the
power limit, so the switch stops supplying the power to this port after
referring to the information of the priority.
Function name:
PoE Configuration
Function description:
In PoE Port Management function, user can configure the settings about PoE.
The switch complies with IEEE 802.3af protocol and be capable of detecting
automatically that whether the device linked to the port on the switch is PD
(Powered Device) or not. The switch also manage the power supplement
based on the Class of the PD, and it will stop supplying the power once the
power required by the PD excesses the Class, Short Circuit or over
temperature occurs.