background image

 

 

SIGNAMAX LLC • www.signamax.eu   

FCC Warning 

 
This device has been tested and found to comply with limits for a 
Class A digital device, pursuant to Part 15 of FCC Rules.    These 
limits  are  designed  to  provide  reasonable  protection  against 
harmful  interference  when  the  equipment  is  operated  in  a 
commercial  environment.    This  equipment  generates  and 
radiates radio frequency energy and, if not installed and used in 
accordance with the user’s manual, it may cause interference in 
which case users will be required to correct interference at their 
own expenses. 

 

CE Warning 
 

This  is  a  Class  A  product.    In  a  domestic  environment,  this 
product may cause radio interference in which case the user may 
be required to take adequate measures.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 065-7532PoE

Страница 1: ...User s Guide 16 Port Nway Fast Ethernet PoE Web Smart Switch Model 065 7532PoE ...

Страница 2: ...he equipment is operated in a commercial environment This equipment generates and radiates radio frequency energy and if not installed and used in accordance with the user s manual it may cause interference in which case users will be required to correct interference at their own expenses CE Warning This is a Class A product In a domestic environment this product may cause radio interference in wh...

Страница 3: ... 065 7532PoE switch consists of 16 PSE PoE ports That can solve the limitation of the power outlet location and offer the system designer a flexible solution to locate the network device everywhere The rack mount size was specifically designed for medium to large workgroups 065 7532PoE switch can be installed where space is limited moreover it provides smooth network migration and easy upgrade to ...

Страница 4: ...nstall this switch please verify your package that contains the following items One 065 7532PoE PoE Switch One Power Cord One CD with User s Manual 16 Port Switch Note If any of these items is found missing or damaged please contact your local supplier for replacement ...

Страница 5: ...orward switching methods IEEE 802 3x flow control for full duplex and back pressure flow control for half duplex Non blocking Non head of line blocking full wire speed forwarding Auto MDI MDI X function for any port Smart plug play Front Panel LEDs LED Indicators of 16 Port PoE 10 100 1000M Switch LED Status Description On Power is on Power Off Power is off On Port is for connection Off No connect...

Страница 6: ...tection functionality for any port It is simple and friendly to up link to another switch without crossover cable PC Other devices to 065 7532PoE PoE Fast Ethernet Switch Via a twisted pair cable straight through 065 7532PoE switch can be connected to PCs servers and other network devices Power Device to 065 7532 PoE Fast Ethernet Switch and ...

Страница 7: ... also comply with IEEE 802 3af Rear Panel Power AC input AC input 90 260V AC 50 60Hz UL Safety Technical Specifications Standards IEEE 802 3af IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX IEEE 802 3x Flow control Features Number of Ports 16 PSE PoE Ports MAC Address 4K Buffer Memory 1 625 Mb Method Store and Forward Filtering Forwarding Rates 100Mbps port 148 800pps 10Mbps 14 880pps Transmission Media...

Страница 8: ...utput 48V DC Per Port Output 15 4 W Max Per Port 16 Ports at Full 15 4 W Output Supported Power Consumption 250 Watts Max Dimensions 440 220 44 mm L x W x H Weight 3 8 kg Operating Temperature 0 to 55 Storage Temperature 20 to 90 Humidity 10 to 90 RH non condensing Certifications FCC Class A CE ...

Страница 9: ...LLC www signamax eu Web Smart Switch Configure Please follow the steps to configure this Web Smart switch Step 1 Use a twisted pair cable to connect this switch to your PC Step 2 Set your PC s IP to 192 168 2 xx ...

Страница 10: ...3 Open the web browser like IE and go to 192 168 2 1 site and then you will see the login screen Key in the ID and the password to pass the authentication ID admin Password admin After the authentication procedure the home page shows up ...

Страница 11: ...On the following home page select the configuration by clicking the icon It includes Administrator Port Management VLAN Setting Per Port Counter Trunk Setting QoS Setting Security Filter Configuration Backup Recovery Miscellaneous Logout ...

Страница 12: ...or Authentication Configuration You can change the user name and the password and click Update to confirm the new change After that you can reset the switch by power off and then power on to take the new user name and the password effectively ...

Страница 13: ...change the IP address by typing the new IP address or select DHCP IP configuration and click Update to confirm the new change and then the message will show Setting Process OK After that you should reset this switch by power off and then power on it to complete the new change ...

Страница 14: ...C www signamax eu Administrator System Status It shows this switch MAC address and system version You can change the new comment of this switch by typing the new comment and click Update to confirm the new change ...

Страница 15: ...SIGNAMAX LLC www signamax eu Administrator Load Default Setting You can click Load to load the factory default setting and then reset the switch by power off and then power on to take it effectively ...

Страница 16: ...SIGNAMAX LLC www signamax eu Administrator Firmware Update Follow the instruction on the screen to update the new firmware Please contact with your sales agents to get the latest firmware information ...

Страница 17: ...SIGNAMAX LLC www signamax eu Administrator Reboot Device You can click Confirm to reboot the device ...

Страница 18: ...this function of the port Speed you can select the 10M or 100M mode of the port Duplex you can select the port is full or half duplex mode Pause you can enable disable the port Backpressure you can enable disable the backpressure of the port Tx Capability you can enable disable TX capability of the port Addr Learning you can enable disable this function of the port ...

Страница 19: ... Port Mirroring Port Mirroring is used to mirror traffic RX TX or TX RX from Source port to Destination port for analysis Select the Destination port from port 1 to port 16 and then select the Source port by clicking the checking box of the port ...

Страница 20: ...onfigure the mode below TX Rate is meant you can set the different transmission rate of this selected port and choose the speed from 1 255 based on two speed levels RX Rate is meant you can set the different receiving rate of this selected port and choose the speed from 1 255 based on two speed levels ...

Страница 21: ...SIGNAMAX LLC www signamax eu Port Management Broadcast Storm Control You can set the threshold of per port to define the status of broadcast packets by clicking Update ...

Страница 22: ...SIGNAMAX LLC www signamax eu VLAN Setting VLAN Mode There are two VLAN modes Port Based VLAN and Tagged VLAN by clicking Change VLAN mode to select the mode you want ...

Страница 23: ...SIGNAMAX LLC www signamax eu VLAN Setting VLAN Member Setting Port Based You can select a group and then click the port number which you want to put it into the selected VLAN group ...

Страница 24: ...AMAX LLC www signamax eu VLAN Setting Multi to 2 Setting This is a special design for easily setting the switch VLAN into VLAN Per Port After this setting all ports can only connect to the destination port ...

Страница 25: ...SIGNAMAX LLC www signamax eu Per Port Counter Counter Category You can read the transmitting and receiving packet of the connecting port ...

Страница 26: ...low Port ID you can select port number you want to include into the same group SA you can select Source Address of the port you want to include into the same group DA you can select Destination Address of the port you want to include into the same group SA DA you can select both Source Address and Destination Address of the port you want to include into the same group ...

Страница 27: ... in First Out the first receiving packet will be firstly transmitted All High before Low packets set in high priority mode will be firstly transmitted completely before packets set in low priority mode Weight Round Robin WRR you can set the ratio of the transmitting packet for the low priority to high priority ...

Страница 28: ... select the port which you want to configure as high priority and then the packets of the port will be firstly transmitted VLAN Tag you can select the port which you want to configure as packets with special Tag will be firstly transmitted IP DS you can select the port which you want to configure as packet with special IP will be firstly transmitted ...

Страница 29: ...SIGNAMAX LLC www signamax eu QoS Setting TCP UDP Port Based There are four modes of TCP UDP priority to select as below F I F O First in First Out the first receiving packet will be firstly ...

Страница 30: ... priority will be firstly transmitted Security Filter MAC Address Filter There are three MAC address tables to select and you can set special MAC address to activate on the selected port When this function is enabled the port will record the first receiving source MAC address as the security MAC address and only allow the packet which has this MAC address to activate on the port ...

Страница 31: ...Configuration You can enable or disable this function of per port If you enable this function there are two modes as below Negative Filter Mode packets compliant with protocol will be dropped Positive Filter Mode packets compliant with protocol will be forwarded ...

Страница 32: ...SIGNAMAX LLC www signamax eu Configuration Backup Recovery Follow the instruction on the screen to update the original setting ...

Страница 33: ...llaneous Setting Aging Time You can set queue aging time into different milliseconds or disable this function VLAN Striding You can enable disable this function IGMP Snooping You can enable disable this function Logout You can click Logout to logout ...

Отзывы: