This chapter presents step-by-step installation instructions for
The Signamax
8-port 100BaseFX fiber switch.
Selecting a Site for the Switch
♦
As with any electronic device, you should place the
Switch where it will not be subjected to extreme
temperatures, humidity, or electromagnetic interference.
Specifically, the site you select should meet the
following requirements:
♦
The room temperature should be between 32 and 104
degrees Fahrenheit (0 to 40 degrees Celsius).
♦
The relative humidity should be less than 90 percent,
non-condensing.
♦
Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards for IEC 801-3,
Level 2 (3V/M) field strength.
♦
Make sure that the switch receives adequate
ventilation. Do not block the ventilation holes on the
side of the switch or the fan exhaust port on the rear of
the switch.
♦
The power outlet should be within 6 feet (1.8meter) of
the switch.