Signamax
065-7111F series Compact Fiber Access Switch
4
User’s Manual
Table 1: Port Status
LED
State
Indication
Steady
The port has established a valid network connection.
LNK stands for LINK.
LNK/
ACT
Flashing
The port is transmitting or receiving data.
ACT stands for ACTIVITY.
Installation
Selecting a Site for the Switch
As with any electronic device, you should place the switch where it will not be
subject to extreme temperatures, humidity, or electromagnetic interference.
Specifically, the site you select should meet the following requirements:
The ambient temperature should be between 32 and 104 degrees
Fahrenheit (0 to 40 degrees Celsius).
The relative humidity should be less than 90 percent, non-condensing.
Surrounding electrical devices should not exceed the electromagnetic
field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength.
Make sure that the switch receives adequate ventilation. Do not block
the ventilation holes on the side of the switch or the fan exhaust port on
the rear of the switch.
The power outlet should be within 6 feet (1.8 meters) of the switch.
Connecting to Your Network
Connect network cables from computers or network segments to the TX (FX)
ports on the back of the unit.
Table 2: Cabling Information
Speed
Connector
Port Speed
Half/Full Duplex
Cable
100BaseTX
RJ-45
100/200 Mbps
100 m, Category 5 or better
STP/UTP
10BaseT
RJ-45
10/20 Mbps
100 m, Category 3, 4, 5 or
better STP/UTP
100BaseFX
multimode
SC, ST,
MT-RJ,
VF-45, or LC
100/200 Mbps
Up to 2 km, 50 or 62.5/125
µ
m
multimode fiber cable
100BaseFX
singlemode
SC
100/200 Mbps
Up to 75 km, 9 or 10/125
µ
m
singlemode fiber cable