Rev 1.5
SignalFire Telemetry
3
SignalFire Telemetry
Model:
SENTINEL-SOLAR-9.0
Hudson, MA USA
www.signal-fire.com
S/N: 00000001
INTRINSICALLY SAFE
SECURITE INTRINSEQUE
CLASS I, DIVISION 1 GROUPS C, D
TEMP CODE: T3
AMBIENT TEMP:
–40ºC to +60ºC
WARNING: SUBSTITUTION OF
COMPONENTS MAY IMPAIR
INTRINSIC SAFETY
AVERTISSEMENT: LA SUBSTITUTION
DE COMPOSANTS PEUT COMPROMETTRE
LA SECURITE INTRINSEQUE
ENTITY PARAMETERS
OUTPUT:
Voc = 5.9 Vdc
Isc = 3.06 A
Pout = 0.8 W
Ca = 999.9 uF
La = 38.18 uH
CONFORMS TO UL STD 913
CERTIFIED TO
CAN/CSA STD C22.2 NO. 157
Intertek
4003827
Exi
[Exi]
Connection to Sentinel Node
Sentinel Compatibility
The current available from the solar system is limited due to the IS certification so the solar system
may not be used for all Sentinel node configurations.
The following configurations are supported:
-
Sentinel Digital
-
Sentinel HART
-
Sentinel Analog in 1-5V mode (with a sensor power draw of less than 8mA)
-
Sentinel Modbus (with a sensor power draw of less than 10mA)
-
Sentinel Turbine
-
Sentinel Thermocouple
Note: The Sentinel Solar cannot be used with a Sentinel Analog operating in 4-20mA mode.