13

14

OPM(optional)

VFL

This device has VFL function, the output power is about 1mW. Press "VFL" button to control red laser on-flashing-

off. When Laser is on, the prompt icon occur at upper right corner. 

OPTICAL TIME DOMAIN REFLECTOMETER

OPTICAL TIME DOMAIN REFLECTOMETER

Press "OPM" button to turn on the OPM function, "         " to open the function menu,"          "to hide the function menu.

2020-06-01      FRI      17:25

Do not stare into beam!

Wavelength

VFL On

Save file

REF set.

REF view

Open file

Offset

dBm

dB

mw

000.00

+00.00

+00.00

1310nm

REF:-70.00dBm

Measure Set. System Set.

Module

About

Files

2020-06-01      FRI      17:25

Do not stare into beam!

dBm

dB

mw

000.00

+00.00

+00.00

1310nm

REF:-70.00dBm

Measure Set. System Set.

Module

About

Files

Function button

2020-06-01      FRI      17:25

测量波长

保存文件

REF

设定

REF

查看

打开文件

偏移量

dBm

dB

nW

0.10

-70.00

0.00

1310nm

REF:-70.00dBm

Save file

Open file

REF set.

REF view

Wavelength

Offset

2020-06-01      FRI      17:25

dBm

dB

nW

0.10

-70.00

0.00

1310nm

REF:-70.00dBm

2020-06-01      FRI      17:25

8_0001.sor

0.00

A-B:10.057 km      1.81 dB      0.00 dB/km

A 0.000 km

2.000km/div

5.00

10.00

15.00

20.00

25.00

30.00

35.00

40.00

45.00

50.00

No.

2/3

2.65

0.18

10.057

-36.08

1.81

File Info:    1310nm        20km      5ns

Dis.

Loss

Ref.

dB/km C.Loss

B 10.057 km

1

2

3

Содержание OTDR ZS1000-A

Страница 1: ...OTDR OTDR U S E R S M A N U A L 2020 09 OPTICAL TIME DOMAIN REFLECTOMETER ZS1000 A...

Страница 2: ...OTDR Measurement Interface OTDR Average Measurement OTDR Real time measurement OTDR Event list OTDR Cursor selection and waveform zoom in out Menu Menu Files Menu Measurement Settings Menu System Sett...

Страница 3: ...atteries Avoiding condensation Sudden changes in temperature should be avoided Do not use the device immediately after moving the device from the cold area to the hot area or when the room suddenly he...

Страница 4: ...00 15 00 20 00 25 00 30 00 35 00 40 00 45 00 50 00 No 2 3 2 65 0 18 10 057 36 08 1 81 File Info 1310nm 20km 5ns Dis Loss Ref dB km C Loss B 10 057 km 1 2 3 OTDR Average Measurement 2020 06 01 FRI 17...

Страница 5: ...ange zoom in or out see P7 for details If you turn on RT analyse it will analyse events when you press REAL again change the cursor position REAL ENTER OTDR Event list Optic fiber start Reflection eve...

Страница 6: ...27 40 28 80 30 20 B 10 057 km A 0 000 km 2020 06 01 FRI 17 25 File Info 20200601 20200601 20200601 20200601 20200601 20200601 20200601 20200601 Files Measure Set System Set About 2020 06 01 FRI 17 25...

Страница 7: ...8 20200527 20200525 20200524 20200526 20200601 20200530 20200529 Rename Delete q 1 w 2 e 3 r 4 t 5 y 6 u 7 i 8 o 9 p 0 a s d f g h j k l z x c v b n m en Enter Space 20200601 _ Files Measure Set Syste...

Страница 8: ...ish Close Files 2020 06 01 FRI 17 25 Self examination Common Storage Administration Other Hardware module information Software module information 2020 06 01 FRI 17 25 Common Storage Administration Oth...

Страница 9: ...dBm dB mw 000 00 00 00 00 00 1310nm REF 70 00dBm Measure Set System Set Module About Files 2020 06 01 FRI 17 25 Do not stare into beam dBm dB mw 000 00 00 00 00 00 1310nm REF 70 00dBm Measure Set Syst...

Страница 10: ...ter to device and finish charging in 8 10 hours Red charge indicator means charging while green means finish Upgrading as following Copy new firmware in TF card Insert TF card OTDR power off Press MEN...

Отзывы: