8.3
Performance Level e, Category 4 or SIL 3
– Conventional
To meet the requirements of safety category 4, performance level "e" for EN ISO 13849-1
and SIL 3 according to EN 62061, the placement of the lines must comply with EN ISO 13849-
2, table D.4 (separate placement, prohibiting of error via short circuits between wires) as
cross-circuit detection is not possible here.