Function
The safety functions in the DC motor output stage are controlled over two digital inputs.
The following table shows the status that the safe inputs ENABLE 1 and ENABLE 2 must
assume to enable normal operation or trigger the safety function.
Input Status
Description
ENABLE 1
ENABLE 2
Open
Open
Safe status of
the drive system
Open
Low
Low
Open
Low
Low
High
High
Drive system ready
If the ENABLE 1 and ENABLE 2 are changed from any status to the "Drive Ready" status,
the DC
motor output stage is not enabled immediately. In order to set the system to “Drive
system ready” status, a change from “Low - Low” to “High - High” must occur.