background image

F

IGURE 

D

IMENSION 

D

IAGRAM 

FOR 

H

ORIZONTAL 

U

NIT 

H

EATER WITH 

S

ERPENTINE 

C

OIL  

(30-H & 40-H) 

 

 

 

F

IGURE 

D

IMENSION 

D

IAGRAM 

FOR 

H

ORIZONTAL 

U

NIT 

H

EATER WITH 

M

ULTI

-

C

IRCUITED 

C

OIL     

(47-H 

TO 

245-H) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

ABLE 

H

ORIZONTAL 

U

NIT 

H

EATER 

S

PECIFICATIONS

 

D

IMENSIONS 

(

IN

M

AX 

T

HROW 

(

FT

M

ODEL

 

F

IGURE 

R

EF

W

(

LB

M

AX

M

TG

H

(

FT

W

/ H

ORIZ

L

OUVERS

 

W

/ V

ERT

L

OUVERS

 

30-H 

22 

13.5 

4.75 

7.50 

15.5 

0.50 

40 

18 

23 

40-H 

22 

13.5 

4.75 

7.50 

15.5 

1.25 

40 

10 

23 

29 

47-H 

27 

16.5 

5.00 

8.5 

7.75  16.25  1.25 

48 

10 

23 

29 

58-H 

27 

16.5 

5.00 

8.5 

9.50 

18.0 

1.25 

48 

10 

28 

35 

62-H 

31.5 

19.5  5.625 

10 

9.50 

19.5 

1.25 

71 

10 

25 

30 

84-H 

31.5 

19.5  5.625 

10 

7.50 

17.5 

1.50 

76 

12 

32 

40 

133-H 

37.0 

24.0  5.875 

10 

7.75  17.75  1.50 

108 

13 

40 

50 

200-H 

42.5 

28.5 

5.50 

10 

9.50 

19.5 

1.50 

148 

15 

50 

64 

245-H 

46.5 

31.5 

5.50 

10 

9.50 

19.5 

1.50 

172 

16 

54 

68 

 

Unit Heaters 

Installation & Operation Manual 

5

 

www.sigmaproducts.com  Tel: (905) 453-0446   Fax: (905) 453-0675 

Rev 2 

Содержание 30-H

Страница 1: ...MANUFACTURERS OF HYDRONIC HEATING PRODUCTS Unit Heaters Installation and Operation Manual www sigmaproducts com Tel 905 453 0446 Fax 905 453 0675 Rev 2...

Страница 2: ...y to provide any scaffolding or other apparatus to allow service or periodic maintenance to this equipment INSTALLATION Unit Heaters Installation Operation Manual 1 www sigmaproducts com Tel 905 453 0...

Страница 3: ...kept clean and free of foreign substances such as excessive joint materials etc For steam systems it is recommended that the unit be mounted level for proper condensate drainage Swing joints should b...

Страница 4: ...s where constant water circulation is used on the pain system A louvered cone air diffuser is available as an optional accessory for vertical unit heaters MAINTENTANCE Motor Lubrication Standard motor...

Страница 5: ...an guard motor frame and fan bolts Check the fan for clearance in the panel orifice and free rotation The heater system should be checked once per year by a qualified technician All maintenance and se...

Страница 6: ...7 50 15 5 0 50 40 9 18 23 40 H 1 22 13 5 4 75 8 7 50 15 5 1 25 40 10 23 29 47 H 2 27 16 5 5 00 8 5 7 75 16 25 1 25 48 10 23 29 58 H 2 27 16 5 5 00 8 5 9 50 18 0 1 25 48 10 28 35 62 H 2 31 5 19 5 5 62...

Страница 7: ...13 625 3 375 V 44 125 30 4 125 2 2 5 1 2 13 UNC 3 9 125 3 480 V 44 125 30 4 125 2 2 5 1 2 13 UNC 3 13 625 3 DIMENSIONS IN MAX MTG HT FT MODEL K L M N P R S WT LB WITHOUT LOUVER WITH LOUVER 40 V 3 11 5...

Страница 8: ...FIGURE 4 TYPICAL PIPING CONNECTIONS Unit Heaters Installation Operation Manual 7 www sigmaproducts com Tel 905 453 0446 Fax 905 453 0675 Rev 2...