General description
X20DM2 simultaneously monitors the concentrations of:
PM10
PM2.5
PM1
TSP, Total Suspended Particle
Each channel measures its average value over the selected interval
time.
The channels are all synchronized and their values are sent to the
connected INFRA Datalogger, which stores them on its local
memory card, and uploads them to the dedicated data server. The last
interval value of channel 1 (PM10) can also be viewed in the
Datalogger display.
2.1 INFRA Field Monitoring system
The INFRA contact placed on the bottom of the cabinet shall be
connected to the INFRA Field Monitoring System by any of the
available INFRA Sensor Cables. This will handle the communication
with the Datalogger
3
. Normally, the cabinet needs also to be
connected to external power supply.
Within INFRA Field Monitoring System it is possible to measure a
number of other quantities
simultaneously
with the dust
measurements, for example:
vibration (geophone) in one direction
vibration (geophone) in three directions
sound level
air blast
weather (wind, rain, humidity, temperature)
etc.
3
The main unit in the INFRA Field Monitoring System