SIGELEI Smax V2 Скачать руководство пользователя страница 2

To reduce the Voltage from 6.0V to 3.0V in 0.1 Volt decrements, or power from 15.0W to 3.0W 

in 0.5 Watt decrements.  

* Select Voltage or Wattage setting in menu 7. 

4. BATTER VOLTAGE 

Battery level indicator 

To check the battery voltage. A fully charged battery will have 4.2V. We recommend charging 

the battery when it falls to 3.3V. Zmax will switch off automatically when the battery level 

reaches 3.1V. 

5. LCD DISPLAY 

Information display 

To select what item to be displayed.  

Battery:

 to display the battery voltage 

Voltage:

 to display the output voltage 

Resistance:

 to display the resistance of atomizer  

6. LCD ON/OFF 

Switch LCD on/off 
When ‘ON’ is selected, the LCD will display your settings when the button is pressed. When 
‘OFF’ is selected, the LCD will not display your settings when the button is pressed. 

7. POWER VOLTAGE 

Select VV or VW 

To choose between variable voltage and variable wattage. 

8. RMS&MEAN 

Select RMS or MEAN voltage. 

*RMS voltage is recommended. 

03 NOTES: 

1. Clean the thread after using in case of rusting and corrosion. 

2. Do not reverse the battery in the tube. 

3. Turn off Zmax when not using. 

4. Do not use the protected batteries.  

5. A hanger is recommended to take the Zmax with you. 

                                                                                           

Error-code:  Short=short circuit of the atomizer 

          Low-V= under voltage 

          HHH= over voltage 

          *When the resistance of the atomizer is below 1.2

Ω

, the Zmax will not work. 

    

Отзывы: