some  of  these  components  vary  by  manufacturer.  Install  components  as 
directed by manufacturer’s instructions. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Existing System: 

Part# 19-151: Low Pressure Regulator 
Part# 19-100-10: 10ft Low Pressure Hose/ Part# 19-100-20: 20ft Hose 
Part# 49-6C:  3/8” NPT X 3/8” flare fitting (hose to regulator connection) 
(*see diagram on pg. 8 for other items you may need for install) 
 

Single 10 or 20 lb Tank: 

Part# 19-151: Low Pressure Regulator 
Part# 19-100-10: 10ft Low Pressure Hose/ Part# 19-100-20: 20ft Hose 
Part# 19-152: Fittings kit (hose to regulator & regulator to tank connections) 
 

Disposable 1 lb Bottle: 

Part# 19-150: Disposable bottle kit (includes regulator #19-151) 
Part# 19-100-10: 10ft Low Pressure Hose/ Part# 19-100-20: 20ft Hose 
 

WARNING:  

-

 

Never  connect  this  heater  directly  to  the  propane/LPG  supply.  This 
heater requires an external regulator that is not supplied.  

Содержание P12000

Страница 1: ...tion Instruction Manual KEEP THIS MANUAL FOR FUTURE REFERENCE P9000 P12000 Model Heaters Please read from beginning to end before installing and operating Heater s Serial __________________ Quality Controlled by Doug Don Form 7 2 247 Issue 1 Apr 8 2011 ...

Страница 2: ...ing the Propane Fuel Pg 8 Propane locker diagram Pg 9 Fuel Connection Options Pg 9 Electrical 12v Fan Pg 10 5 Lighting Procedure Pg 11 Flame Characteristics Pg 11 6 Maintenance Pg 12 Thermocouple Orifice Cleaning Pg 12 Troubleshooting Pg 13 Replacement Parts Pg 14 7 Warranty Policy Pg 15 8 Registering your Warranty Pg 18 Packing List 1 P9000 P12000 Heater Fireplace 2 2 5 x 28 Double walled Stainle...

Страница 3: ... Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this appliance Do not install this appliance in spaces containing internal combustion engines fuel tanks or joints and fittings of their fuel systems All installations must conform with local codes or in the absence of any codes with the current National Fuel Gas Code ANSI Z223 1 or current CAN CGA B149 Installat...

Страница 4: ...These heaters are equipped with a CGA AGA approved safety gas valves If the flame should ever be extinguished the gas will be shut off automatically Manual ignition involves lighting the heater with a long barbeque lighter with the door open and therefore avoids any initial build up of unburned gas The installation of a gas detector is recommended for all LPG appliances NOTE When using the P12000 ...

Страница 5: ... cabin Plan your heaters location prior to installing to ensure the location chosen will fit the specifications and safety clearances Safety Clearances Above 20 Front 18 Sides 2 Below 2 Combustible material such as the deck ceiling or walls that are closer to the heater then the specified safety clearances must be insulated with insulation or millboard with a metal liner a 5 standoff is best for a...

Страница 6: ...e clamp is left on the pipe and only removed after or during installing Cut with fine tooth hack saw blade then use a round file to remove the large burrs in the inside of the pipe Use caution as the flexible pipe can be easily damaged Locate and run the vent pipe such that no low points occur where water or debris can accumulate and thus block the exhaust or intake The direct vent chimney is flex...

Страница 7: ...the flexible pipe on the heater It is very important that the small pipe fit tightly against the flue collar on the heater even adding some muffler tape or tin foil to fill in any gaps of the pipe to ensure an airtight connection the cap and any other connections are not as important Step 5 Make whatever bends are necessary in the flexible pipe and push into the deckfitting Step 6 Attach the back ...

Страница 8: ... 9 Reasons for having a separate low pressure regulator for each appliance 1 The ABYC Standards state 1 7 2 Each appliance shall be served by a separate low pressure regulator and supply line that shall originate inside the cylinder locker We recommend you follow the ABYC standard 2 The regulator only serves a very low pressure of gas through a small 3 8 gas line and depending on the distance 1 re...

Страница 9: ...for other items you may need for install Single 10 or 20 lb Tank Part 19 151 Low Pressure Regulator Part 19 100 10 10ft Low Pressure Hose Part 19 100 20 20ft Hose Part 19 152 Fittings kit hose to regulator regulator to tank connections Disposable 1 lb Bottle Part 19 150 Disposable bottle kit includes regulator 19 151 Part 19 100 10 10ft Low Pressure Hose Part 19 100 20 20ft Hose WARNING Never conn...

Страница 10: ... brought to the wire connectors of the fans ON OFF switch through the grommet installed at the bottom of the heater The fan installed in this heater is CE approved and EM compliant for FCC and CSA regulations The fan must have an inline fuse rated at 2 amps If applicable this appliance must be electrically grounded in accordance with local codes or in absence of local codes with the National Elect...

Страница 11: ...dow external surfaces and the vent pipe of the heater get very hot and can cause burns NOT closing the door of the heater properly may cause depletion of oxygen within the cabin exhaust gas to enter the cabin possibly including Carbon Monoxide Carbon Monoxide CO is a colorless tasteless invisible toxic gas which can cause serious health problems or death NOTE Only on first lighting the lubricating...

Страница 12: ... holding the black plates 2 Next remove all the screws on the sides of the heater careful hold on to the front cover and remove the top and bottom Open the door wide and pull back slightly from the front cover to remove the 2 connectors on the rocker switch use needle nose pliers 3 Using a 5 16 wrench disconnect the brass nut at one end of the thermocouple located on the back of the control valve ...

Страница 13: ... regulator solenoid Check that knob is exactly on LOW which is 9 o clock when pressed in Orifice is clogged due to dirt build up or material in new hose installation Fire does not stay lit when knob released Depress knob light burner and almost close door Release knob and then CLOSE COMBUSTION CHAMBER DOOR Check that the door seal is good Check that the internal exhaust pipe is installed correctly...

Страница 14: ...coupling Part 19 030 2 5 x 18 Stainless Flue Guard Part 19 100 10 10ft Low Pressure Propane Hose Part 19 100 20 20ft Low Pressure Propane Hose Part 19 150 Disposable bottle kit includes regulator 19 151 Part 19 151 Low Pressure Regulator Part 19 152 Fittings Kit hose to regulator regulator to tank connections Part 19 080 Stainless Exhaust Cap Guard Part 19 200 Weather Guard to use alone Part 19 21...

Страница 15: ...st have been received or a proof of purchase must be presented to receive the warranty 1 The customer can contact us directly to settle any warranty issues We are pleased to help Call us toll free 1 800 659 9768 or email info dickinsonmarine com 2 If the customer is returning a complete product they see as defective be sure the product has been assembled correctly and is being used correctly If yo...

Страница 16: ...uch parts have not been improperly repaired altered or tampered with or subjected to misuse abuse or exposed to corrosive conditions This warranty however is limited by certain exclusions time limits and exceptions as listed below Read these limitations and exclusions carefully TIME LIMIT This warranty is given too and covers only the original purchaser Coverage terminates one year from the date o...

Страница 17: ...order to protect any warranty rights you must promptly notify Dickinson Give name address and model name location of unit description of problem and where you can be reached during business hours RESERVED RIGHT TO CHANGE Dickinson reserves the right to make changes or improvements to products it produces in the future without imposing on itself any obligations to install the same improvements in t...

Страница 18: ...Form I have read and understand the Limited Warranty and the entire Instruction Manual and agree to the terms and conditions PLEASE PRINT Name ______________________________________________________ Address ____________________________________________________ Phone ______________________________________________________ Heater Model Name ___________________________________________ Heater Serial ____...

Страница 19: ...arine com Website www sigmarine com All rights reserved No part of this manual may be reproduced without permission in writing from Sig Marine Sig Marine also reserves the right to modify or change without notice any materials applications equipment accessories and or prices All measurements and weights are approximate ...