PowerSync Service Analyzer Reference Manual
February 8, 2010
Sifos Technologies page
25
3.1.3.
Classification Service and Interoperability Tests
Classification Service Tests
report the behavior of the PoE service
connection to each PD classification (0, 1, 2, or 3). Information
reported includes maximum power capacity available by PD
classification as well as the ability of the PoE connection to deliver the
appropriate power capacity to PD classification signatures that are
borderline for each PD classification.
Parameter
Description
Range of Outcomes
CLASS_0_PWR:
Power Available to a nominal PD Classifying as Class 0
to assure a minimum of 12.95 watts is available to PD
0 to 20 Watts
PASS / FAIL
CLASS_1_PWR:
Power Available to a nominal PD Classifying as Class 0
to assure a minimum of 3.84 watts is available to PD
0 to 20 Watts
PASS / FAIL
CLASS_2_PWR:
Power Available to a nominal PD Classifying as Class 0
to assure a minimum of 6.49 watts is available to PD
0 to 20 Watts
PASS / FAIL
CLASS_3_PWR:
Power Available to a nominal PD Classifying as Class 0
to assure a minimum of 12.95 watts is available to PD
0 to 20 Watts
PASS / FAIL
CLASS_0_RNG:
Power Available to PD with Borderline Class 0 Signatures
to assure all Class 0 PD’s receive the same power allocation
PASS / FAIL
CLASS_1_RNG:
Power Available to PD with Borderline Class 1 Signatures
to assure all Class 0 PD’s receive the same power allocation
PASS / FAIL
CLASS_2_RNG:
Power Available to PD with Borderline Class 2 Signatures
to assure all Class 0 PD’s receive the same power allocation
PASS / FAIL
CLASS_3_RNG:
Power Available to PD with Borderline Class 3 Signatures
to assure all Class 0 PD’s receive the same power allocation
PASS / FAIL
3.1.4.
PoE Service Test Suite Reporting
The Sifos
PoE Service Analyzer
includes a colorful
Microsoft Excel
Test Report (
see Figures 3.4, 3.6
) that can be
automatically produced upon completion of the full set of PoE Service Access Tests. The report performs
limit checking
and
color formatting
of each test outcome. It also presents a graphical depiction both required and available power to
each PD Class, PoE line voltage and line noise across PD power levels, and transient (burst) power performance of the PoE
service.
Figure 3.3
:
Classification Service Tests
Figure 3.4
PoE Service Spreadsheet Report Showing Fully Compliant Servi
ce
Figure 3.5
PoE Service Text
File Report