Perimeter Detection System - Installation manual 

 

 

 

 

 

 

The  manual  describes  installation  and  configuration  of  the  P  detection  system  and  is 
intended exclusively for authorized partners of the manufacturer SIEZA, a.s. 

Updated: 02/11/2016 

 

Содержание Peridect CUP+

Страница 1: ...tion System Installation manual The manual describes installation and configuration of the PERIDECT detection system and is intended exclusively for authorized partners of the manufacturer SIEZA a s Updated 02 11 2016 ...

Страница 2: ...the LCP Terminal Board 12 2 3 2 LED Signalling of CUP and LCP 13 2 4 LIP Line Input PERIDECT 13 2 5 LPP Line Protection PERIDECT 13 2 6 IOP LAN RS485 I O Module PERIDECT 14 2 6 1 Connecting the IOP Terminal Board 14 2 7 LSP Line Separator PERIDECT 15 2 8 Block Diagram of the System 15 3 Technical Specification of PERIDECT 16 3 1 PERIDECT CUP Control Unit 16 3 2 PERIDECT LCP Line Controller 16 3 3 ...

Страница 3: ... reduces false alarms caused by weather conditions rain wind hail lightning bolts and enables operation under these conditions without need to manually or automatically adjust the system sensitivity settings 1 2 System Topology The system consists of basic components CUP control unit LCP line controller DSP detection sensor The system can be supplemented by additional elements according to the spe...

Страница 4: ...gured freely The number of outputs can also be expanded by IOP LAN or IOP RS485 modules via ETH and RS485 ports These modules are equipped with relay outputs and can be used to connect the PERIDECT system outputs to inputs of equipment made by other manufacturers security central DVR etc while maintaining the galvanic separation of these systems PERIDECT acts as a fully autonomous alarm system and...

Страница 5: ... roof and therefore has to be installed using a cover with two screws that always point towards the ground The detectors are connected using a special twin core cable of exterior design i e a cable with coating resistant to UV radiation and outside environment The Standard version of detection perimeter always comes with pre connected detectors When ordering a detection line it is necessary to def...

Страница 6: ... This is used as a measure for cables in production with an installation addition of approximately 40 cm added for turns at the detector and around the post For reasons of weight and dimensions of the detectors the Antivandal version detection lines come in packages of maximum of 50 interconnected detectors The delivered segments are connected at the installation site to make a complete perimeter ...

Страница 7: ...llation method In order to be able to be placed inside posts of different shapes and diameters the detection sensor itself is attached to a sheet metal holder with springs the so called bridge that ensures its fixation inside the post Sometimes it is appropriate to fasten the sensor holder e g using an S shaped wire there is a hole in the holder for this purpose so that it does not sink deeper ins...

Страница 8: ...le of the single fence panel outside the tensioning wires of the fence The cable is fixed to the fencing by the fastening ties after approximately each 25 cm 10 pcs fastening ties between each two detectors to avoid the impacts of the wiring to the fencing caused by the wind in order to reduce the probability of causing the false alarms Before connecting the line the outside black insulation is re...

Страница 9: ... 8 Detector placement and the method of running the cables across the fence Inner arrangement of the detector ...

Страница 10: ...ntrol unit is equipped with several external control and communication modules There are OC type outputs which are freely programmable and can be used for purposes such as basic system status indication The outputs use semi conductor switches It is not recommended to use higher switching voltage than that used to power the CUP unit or current consumption exceeding 250 mA The evaluation unit is pla...

Страница 11: ...e Tamper terminal board connection of external protective contact tamper from the assembly box or another cover NC contact Supply terminal board supply voltage of 9 16 VDC ETH connector for connecting CUP to the data network communicating with other elements in the data network communication with other network elements IOP LAN cameras using the Onvif protocol RS 232 data line used for connection o...

Страница 12: ... 11 0V Uc 1 2 3 4 5 6 0V Schematic internal connection of CUP s outputs and their assignment to connectors UC power voltage 9 16V DC Output terminals for detailed connection see picture below RS485 ...

Страница 13: ...al modules of the line to process them and send the results to the CUP control unit using the RS232 serial interface 2 3 1 Connecting the LCP Terminal Board LCP Line Controller Supply terminal board supply voltage of 9 16 VDC RS232 connector used for connection and communication with the CUP control unit It s possible to use standard UTP patchcord Data line used for connection and communication wi...

Страница 14: ...ouble balanced inputs the first input is equipped with balancing resistors of 2 x 1 2 kΩ the second one is fitted with 2 x 3k3 resistors They are connected parallel to the detection line at any point of its length The identification of the LIP module is defined using its address In practice the input can be used for devices such as a magnetic contact at the gate used to indicate whenever it is ope...

Страница 15: ...xternal devices such as magnetic contacts motion detectors etc The output module is placed inside a plastic casing suitable for installation on a DIN rail For outside environment it has to be provided with appropriate IP protection 2 6 1 Connecting the IOP Terminal Board Terminal board used to connect the outputs complete switching contact is brought out for each relay Relay outputs are in order N...

Страница 16: ...ator is equipped by two pairs of cable outlets These are both equal no need to distinguish the inlet from the outlet The line separators feature a built in overvoltage protection That means that as long as there are separators fitted within a line it is fine to only provide enough overvoltage protection modules to satisfy the rule of 15 25 LPP modules per line 2 8 Block Diagram of the System m TCP...

Страница 17: ...wer supply powered by the line controller bus Consumption 2 mA max Operational temperature range 40 C to 85 C Inputs 2x double balanced balancing resistors of 2 x 1k2 and 2 x 3k3 Electronic elements protection IP65 Dimensions 50 x 30 x 20 mm outer casing 110 x 110 x 40 mm 3 4 DSP Detection Sensor PERIDECT Power supply powered by the line controller bus Consumption 2 mA max Operational temperature ...

Страница 18: ...dule Supply voltage 9 16 VDC Consumption 120 mA 620 mA at all relays switched on Operational temperature range 25 C to 60 C Protection IP20 Dimensions 190 x 130 x 50 mm In case of connecting Expander module it is necessary to connect it ONLY when the IOP module is powered off 3 8 PERIDECT IOP EXP I O Expansion Module Consumption The consumption of IOP LAN or IOP RS485 is increased by 50 mA when th...