SAFETY

 

1.

 

Apply

 

power

 

only

 

after

 

reviewing

 

wiring

 

diagrams

 

printed

 

on

 

the

 

back

 

of

 

this

 

card

 

&

 

in

 

Instruction

 

Manual,

 

Ch.

 

2

 

2.

 

Apply

 

gas

 

flow

 

only

 

after

 

checking

 

plumbing

 

connections

 

for

 

leaks

 

3.

 

NEVER

 

TEST

 

FOR

 

LEAKS

 

WITH

 

LIQUID

 

LEAK

 

DETECTOR.

 

If

 

liquid

 

seeps

 

into

 

the

 

electronics

 

or

 

the

 

hidden

 

sensor

 

compartment,

 

the

 

instrument

 

may

 

be

 

damaged.

 

Instead,

 

use

 

a

 

pressure

decay

 

test

 

(if

 

liquid

 

MUST

 

be

 

used

 

at

 

all,

 

limit

 

it

 

to

 

the

 

fittings

 

and

 

keep

 

it

 

off

 

the

 

body

 

of

 

the

 

instrument).

 

 

INSTALLATION

 

1.

 

Consult

 

the

 

instrument’s

 

Data

 

Label

 

(on

 

the

 

rear

 

of

 

the

 

instrument)

 

for

 

ALL

 

proper

 

operating

 

parameters.

 

If

 

the

 

information

 

on

 

the

 

Data

 

Label

 

does

 

not

 

match

 

your

 

process

 

conditions,

 

contact

 

your

 

Representative

 

or

 

Sierra

 

Instruments

 

Customer

 

Service.

 

2.

 

Install

 

a

 

10

 

micron

 

in

line

 

filter

 

upstream

 

of

 

your

 

instrument.

 

If

 

the

 

gas

 

contains

 

any

 

moisture,

 

use

 

an

 

appropriate

 

dryer

 

or

 

desiccant.

 

Particles

 

larger

 

than

 

10

 

micron

 

and

 

moisture

 

may

 

damage

 

your

 

instrument.

 

3.

 

Mount

 

according

 

to

 

Data

 

Label

 

orientation.

 

Horizontal

 

flow

 

is

 

preferable

 

and

 

factory

 

default

 

UNLESS

 

the

 

factory

 

calibration

 

was

 

performed

 

specifically

 

for

 

vertical

 

flow

 

upward

 

or

 

downward,

 

as

 

listed.

 

Orientation

 

is

 

listed

 

on

 

the

 

Data

 

Label

 

and

 

on

 

the

 

Calibration

 

Certificate.

 

4.

 

DO

 

NOT

 

APPLY

 

POWER

 

TO

 

THE

 

OUTPUT

 

LOOP

.

 

This

 

is

 

NOT

 

a

 

loop

powered

 

device.

 

5.

 

Apply

 

power

 

only

 

after

 

reviewing

 

wiring

 

diagrams

 

printed

 

on

 

the

 

back

 

of

 

this

 

card

 

&

 

in

 

Instruction

 

Manual,

 

Ch.

 

2

 

Power

 

is

 

applied

 

via

 

the

 

HD

 

DB15

 

connector.

 

The

 

CAT

5

 

RJ45

 

connector

 

is

 

for

 

the

 

Sierra

 

Remote

 

Pilot

 

Module

 

or

 

provided

 

‘CRN’

 

cable.

 

DO

 

NOT

 

use

 

the

 

CAT5

 

RJ45

 

port

 

for

 

Ethernet—damage

 

to

 

your

 

computer

 

system

 

or

 

the

 

instrument

 

may

 

occur.

 

 

OPERATION

 

1.

 

Power

 

the

 

unit.

 

If

 

you

 

are

 

using

 

the

 

Sierra

 

provided

 

power

 

supply,

 

it

 

is

 

recommended

 

you

 

attach

 

the

 

D

sub

 

connector

 

to

 

the

 

Smart

Trak

 

2

 

before

 

plugging

 

the

 

adapter

 

into

 

the

 

wall.

 

The

 

unit

 

may

 

take

 

longer

 

to

 

start

 

than

 

normal

 

if

 

otherwise.

 

This

 

will

 

not

 

damage

 

the

 

unit.

 

The

 

green

 

LED

 

above

 

the

 

RJ45

 

connector

 

will

 

light

 

when

 

the

 

unit

 

powered.

 

2.

 

Our

 

Mass

 

Flow

 

Controllers

 

are

 

shipped

 

with

 

a

 

zero

 

setpoint

 

in

 

Automatic

 

valve

 

operation

 

mode.

 

For

 

safety

 

considerations,

 

it

 

is

 

recommended

 

you

 

confirm

 

this

 

prior

 

to

 

applying

 

gas

 

to

 

the

 

unit.

 

3.

 

Apply

 

the

 

gas

 

listed

 

on

 

the

 

Data

 

Label

 

to

 

the

 

inlet

 

at

 

the

 

recommended

 

pressure

 

(listed

 

on

 

the

 

Data

 

Label/Calibration

 

Certificate).

  

Your

 

Smart

Trak

 

2

 

Meter

 

will

 

begin

 

to

 

measure

 

mass

 

flow.

 

This

 

will

 

be

 

displayed

 

on

 

the

 

user

 

software

 

or

 

display

 

module

 

that

 

you

 

have

 

hooked

 

up.

 

4.

 

Mass

 

Flow

 

Controllers

 

will

 

need

 

a

 

setpoint

 

input

 

in

 

order

 

to

 

control

 

flow.

 

Do

 

so

 

carefully!

 

You

 

can

 

digitally

 

input

 

a

 

setpoint

 

using

 

the

 

provided

 

User

 

Software

 

or

 

Pilot

 

Module,

 

or

 

control

 

directly

 

with

 

your

 

analog

 

setpoint

 

source.

 

NOTE:

 

You

 

can

 

change

 

the

 

setpoint

 

source

 

type

 

using

 

the

 

software

 

or

 

Pilot

 

Module.

 

The

 

unit

 

ships

 

in

 

the

 

configuration

 

initially

 

chosen

 

(or

 

default

 

if

 

not

 

specified).

 

This

 

information

 

is

 

also

 

listed

 

on

 

the

 

Data

 

Label

 

and

 

on

 