Sierra 240/241 Series Instruction Manual
Chapter 1 Introduction
IM-240
1-1
Chapter 1 Introduction
InnovaMass
®
Multivariable Mass Vortex Flow Meter
Sierra Instruments’ InnovaMass 240 In-Line and the InnovaMass 241 In-
sertion vortex flow meters provide a reliable solution for process flow
measurement. From a single entry point in the pipeline, 240 and 241 of-
fer precise measurements of mass or volumetric flow rates.
Multivariable Mass Flow Meters
Mass flow meters utilize three primary sensing elements: a vortex shed-
ding velocity sensor, an RTD temperature sensor, and a solid state pres-
sure sensor to measure the mass flow rate of gases, liquids, and steam.
Meters are available as loop powered devices or with up to three 4-20
mA analog output signals for monitoring your choice of the five process
variables (mass flow, volumetric flow, temperature, pressure and fluid
density). The Energy Monitoring option permits real-time calculation of
energy consumption for a facility or process.
Volumetric Flow Meters
The primary sensing element of a volumetric flow meter is a vortex
shedding velocity sensor. Meters are loop powered. The analog 4-20
mA output signal offers your choice of volumetric or mass flow rate.
Mass flow rate is based on a constant value for fluid density stored in the
instrument’s memory.
Both the mass and volumetric flow meters can be ordered with a local
keypad/display which provides instantaneous flow rate, total, and process
parameters in engineering units. A pulse output signal for remote totali-
zation and MODBUS or HART communications are also available. In-
novaMass digital electronics allows for easy reconfiguration for most
gases, liquids and steam. The Sierra InnovaMass 240 and 241 vortex
meters’ simple installation combines with an easy-to-use interface that
provides quick set up, long term reliability and accurate mass flow meas-
urement over a wide range of flows, pressures and temperatures.
Using This Manual
This manual provides information needed to install and operate both the
240 In-Line and 241 Insertion InnovaMass vortex flow meters.
Chapter 1 includes the introduction and product description
Chapter 2 provides information needed for installation
Chapter 3 describes system operation and programming
Chapter 4 provides information on HART and MODBUS protocols
Chapter 5 covers troubleshooting and repair
Appendix A - Product Specifications, Appendix B – Approvals,
Appendix C – Flow Meter Calculations, Appendix D – Glossary of
Terms
Содержание INNOVA-MASS 240-VT
Страница 123: ...Sierra 240 241 Series Instruction Manual Appendix A Specifications IM 240 A 1 Appendix A Product Specifications...
Страница 124: ...Appendix A Specifications Sierra 240 241 Series Instruction Manual A 2 IM 240...
Страница 125: ...Sierra 240 241 Series Instruction Manual Appendix A Specifications IM 240 A 3...
Страница 126: ...Appendix A Specifications Sierra 240 241 Series Instruction Manual A 4 IM 240...
Страница 127: ...Sierra 240 241 Series Instruction Manual Appendix A Specifications IM 240 A 5...
Страница 128: ...Appendix A Specifications Sierra 240 241 Series Instruction Manual A 6 IM 240...
Страница 129: ...Sierra 240 241 Series Instruction Manual Appendix A Specifications IM 240 A 7...
Страница 130: ...Appendix A Specifications Sierra 240 241 Series Instruction Manual A 8 IM 240...
Страница 131: ...Sierra 240 241 Series Instruction Manual Appendix A Specifications IM 240 A 9...
Страница 132: ...Appendix A Specifications Sierra 240 241 Series Instruction Manual A 10 IM 240...
Страница 133: ...Sierra 240 241 Series Instruction Manual Appendix A Specifications IM 240 A 11...
Страница 134: ...Appendix A Specifications Sierra 240 241 Series Instruction Manual A 12 IM 240...
Страница 135: ...Sierra 240 241 Series Instruction Manual Appendix A Specifications IM 240 A 13...