Sierra HART 600 Series Скачать руководство пользователя страница 2

 

 

 

 
GLOBAL SUPPORT LOCATIONS: WE ARE HERE TO HELP! 

 
 

CORPORATE HEADQUARTERS  

5 Harris Court, Building L   Monterey, CA 93940 

Phone (831) 373-0200   (800) 866-0200    Fax (831) 373-4402 

www.sierrainstruments.com

  

   

EUROPE HEADQUARTERS  

Bijlmansweid 2  1934RE  Egmond aan den Hoef   
The Netherlands 

Phone +31 72 5071400   Fax +31 72 5071401 

 

ASIA HEADQUARTERS  

Second Floor Building 5, Senpu Industrial Park 

25 Hangdu Road Hangtou Town 

Pu Dong New District, Shanghai, P.R. China  

Postal Code 201316 

Phone:  + 8621 5879 8521    Fax: +8621 5879 8586 

 
 

 

 

IMPORTANT CUSTOMER NOTICE- OXYGEN SERVICE 

Sierra Instruments, Inc. is not liable for any damage or personal injury, whatsoever,

 

resulting from the use of Sierra Instruments standard mass 

flow meters for oxygen

 

gas. You are responsible for determining if this mass flow meter is appropriate for

 

your oxygen application. You 

are responsible for cleaning the mass flow meter to

 

the degree required for your oxygen flow application.

 

 

 

© COPYRIGHT SIERRA INSTRUMENTS 2012 

No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any 
human or computer language, in any form or by any means, electronic, mechanical, manual, or otherwise, or disclosed to third parties 

without  the  express  written  permission  of  Sierra  Instruments.  The  information  contained  in  this  manual  is  subject  to  change  without 
notice. 

TRADEMARKS 

SteelMass

®

, Compod™, and FlatTrak™ are trademarks of Sierra Instruments, Inc. Other product and company names listed in this manual 

are trademarks or trade names of their respective manufacturers. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание HART 600 Series

Страница 1: ...600 700 Series HART Instruction Manual HART Device Specification for Models 640S 760S 780S and 780S UHP Thermal Mass Flow Meters Part Number IM600 700 HART Rev V1 May 2013...

Страница 2: ...ass flow meters for oxygengas You are responsible for determining if this mass flow meter is appropriate for your oxygen application You are responsible for cleaning the mass flow meter tothe degree r...

Страница 3: ...ning Always remove main power before disassembling any part of the mass flow meter Caution Before making adjustments to the device verify the flow meter is not actively monitoring or reporting to any...

Страница 4: ...Service Technical Assistance If you encounter a problem with your flow meter review the configuration information for each step of the installation operation andsetup procedures Verify that your sett...

Страница 5: ...5 Table of Contents Table of Contents 5 Chapter 1 Introduction 6 HART Commands 6 640S 780S SIP Configurator 6 Device Variables and Dynamic Variables 6 Drawings 9...

Страница 6: ...through the 600 700 Series HART RS 232 Serial port and a PC USB RS 232 port Device Variables and Dynamic Variables Through the Dynamic Variable Assignment the Device Variables are mapped to the four...

Страница 7: ...nds per hour 83 lb day lb day pounds per day Volume Flow Totalizer HART Variable Menu Units List Actual Flow Meter Measurement Device Variable Classification Code 68 Code Description 41 l SL Standard...

Страница 8: ...Variables Flow Totalizer User Full Scale K Factor Byte 0 3 Current Byte 4 PV unit code Byte 5 8 PV Byte 9 SV unit Code Byte 10 13 SV Byte 14 TV unit Code Byte 15 18 TV Byte 19 FV unit Code Byte 20 23...

Страница 9: ...9 Drawings See drawings below for Analog output and HART Connection Figure 1 Point to point with Non Isolated 4 20 mA loop Figure 2 Point to point with Isolated 4 20 mA loop...

Страница 10: ...10 Figure 3 Multi drop digital signal only 4 20mA must be set to a fixed 4 mA Consult factory...

Отзывы: