Note and Safety Information

 

We use caution and warning statements throughout this book to draw

 

your 

attention to important information. 

 

 

 

 

  Warning! 

 

Caution! 

This statement appears with information that 
is important to protect people and equipment 
from damage. Pay very close attention to all 
warnings that apply to your application. 

This statement appears with information that is 
important for protecting your equipment and 
performance. Read and follow all cautions that 
apply to your application. 

                                                              

 

Receipt of System Components

 

When receiving a Sierra mass flow meter, carefully check the outside packing carton 
for damage incurred in shipment. If the carton is damaged, notify the local carrier 
and submit a report to the factory or distributor. Remove the packing slip and 
check that all ordered components are present. Make sure any spare parts or 
accessories are not discarded with the packing material. Do not return any 
equipment to

 

the factory without first contacting Sierra Customer Service

.

 

 
Technical Assistance

 

If you encounter a problem with your flow meter, review the configuration 
information for each step of the installation, operation, and

 

setup procedures. 

Verify that your settings and adjustments are consistent with factory 
recommendations.

 

Installation and troubleshooting information can be found in 

th

SteelMass™ 640S

FlatTrak™ 780S

 (includes 760S), or 

780S UHP

 product 

manual.

 

 

If the problem persists after following the troubleshooting procedures

 

outlined in the 

640S or 780S product manuals, contact Sierra Instruments by fax or by E-mail

 

(see inside front cover). For urgent phone support you may call (800) 866-0200 or 
(831) 373-0200 between 8:00 a.m. and 5:00 p.m. PST. In Europe, contact Sierra 
Instruments Europe at +31 20 6145810. In the Asia-Pacific region, contact Sierra 
Instruments Asia at +86-21-58798521. When contacting Technical Support, make 
sure to include this information: 

 

 

The flow range, serial number, and Sierra order number (all 
marked on the meter nameplate) 

 

The software version (visible at start up) 

 

The problem you are encountering and any corrective action taken 

 

Application information (gas, pressure, temperature and piping 

Содержание Foundation Fieldbus 600 Series

Страница 1: ...00 Series Foundation Fieldbus Instruction Manual Foundation Fieldbus Interface Specification for Models 640S 760S 780S and 780S UHP Thermal Mass Flow Meters Part Number IM600 700 FF Rev V1 1 December...

Страница 2: ...d mass flow meters for oxygengas You are responsible for determining if this mass flow meter is appropriate for your oxygen application You are responsible for cleaning the mass flow meter tothe degre...

Страница 3: ...ing Always remove main power before disassembling any part of the mass flow meter Caution Before making adjustments to the device verify the flow meter is not actively monitoring or reporting to any m...

Страница 4: ...erra Customer Service Technical Assistance If you encounter a problem with your flow meter review the configuration information for each step of the installation operation and setup procedures Verify...

Страница 5: ...Foundation Fieldbus Interface Configurations 9 AI AO Blocks 9 MODBUS_REGS_ 1 through 4 9 Chapter 5 Configuring the FF BUS Using NI FBUS Configurator 11 Getting Started Configuring FF Bus Using NI FBU...

Страница 6: ...detailed information about Foundation Fieldbus go to http www fieldbus org The Sierra Instruments 600 700 Series mass flow meters can be ordered with the optional Foundation Fieldbus FF BUS Communicat...

Страница 7: ...H1 network connections are labeled as FF 1 and FF 2 This is on the 2 position terminal block on the upper left shown below in Figure 1 These are not polarity dependent If you are using multiple shiel...

Страница 8: ...he FF BUS interface For special configuration the user will only need a rudimentary knowledge of Modbus MODBUS_REG_SETUP_1 to 4 This is where AI1 2 3 4 and AO are configured as PV1 2 3 4 and Final Val...

Страница 9: ...d open for customer configuration MODBUS_REGS_ 1 through 4 The Transducer Block also has four groups of Modbus registers that can be used for static setup inputs and outputs for variables such as fact...

Страница 10: ...10 Serial number char 1 2 Serial number char 3 4 Serial number char 5 6 Serial number char 7 8 Serial number char 9 10 Decimal Point 4 26 1 Table 2 Factory Static MODBUS Registers...

Страница 11: ...e available can be downloaded from our web site at http www sierrainstruments com userfiles file dd_files zip Getting Started Configuring FF Bus Using NI FBUS Configurator 1 Start the NI FBUS COM mana...

Страница 12: ...ellow highlights disappear click Auto mode The configuration below was already done at the factory After completing the configuration you should be able to read the variables being returned from your...

Страница 13: ...so they can be read by the FF BUS under PV_UNIT_1 2 3 4 and FINAL_VALUE_AO_UNIT See Figure 5 User Full Scale Factory Full Scale K Factor Accumulated Total Flow Current Flow Rate Figure 4 Screen Showi...

Страница 14: ...he Modbus and the FF BUS boards inside the meter The Modbus Instrument Address must always be set to 1 The MODBUS _COM_SETUP must always set as shown below BaudRate 9600 Baud Stop_Bits 1 Parity None C...

Страница 15: ...har 1 2 R Unsigned short integer 2 Char ASCII String 11 Flow unit char 3 4 R Unsigned short integer 2 Char ASCII String 12 Flow unit char 5 6 R Unsigned short integer 2 Char ASCII String 13 Totalizer...

Страница 16: ...e of the unit as set by the manufacturer This would be the full scale flow available to FF BUS Use data type 16 bit short integer Byte order 1 0 This register would work in one of the 40 Modbus regist...

Страница 17: ...lve characters long and always starts with SN or 53 4E 3A in Hex 26 Decimal Point Of The Flow Totalizer This register indicates the location of the decimal point in the actual flow totalizer Returned...

Страница 18: ...ndation Fieldbus Board polls the Modbus board Every time a message is passed between the Foundation Fieldbus board and the Modbus board the FF_BUS to MODBUS_COM LED will blink yellow When the Foundati...

Отзывы: