II. FIREPLACE INSERT INSTALLATION
A. Installation into a Factory-Built Fireplace
Your Cricket has been tested by W arnoch-Hersey
International for installation in the following SPECIFIED
zero clearance fireplaces (ZCF) which are furnished with
an 8" m inim um listed chim ney system . The Cricket m ust
be installed in a ZCF with the rear m anifold and blower
option.
Heatilator
Models 3036, 3038, 3130, 3138, 3336R,
3336L, 3042, 3048, 3342R, 3342L, HE36BG, HE42B,
HE28B, TD36A, TD36B, TD42B, TD46BI, HF42A, HF36A,
Mark 123, HB36, AM, NA42-A1
M ajestic
Models M28, M36, M36AO, M42, L-36, L-36B,
L-42, L-42R, L-42L, L-42B, MD-36, MD36AO, MD-36R,
MD-36L, M.H.C.36, MBUC36, MBUC42, MRC36, RC36,
W MII-36, W MII-42, MFC-36, MEC-36A, MEC-36F, MECB-
36, MBC-36A, MB-42, MBU-36, MD-42, MD-42AO, MHC-
28, MHC-42
M arco
Models 36-X, 36-1X, 36N-X, 36NI-X, DW F-36CF,
DW F-36GO-X, DW F-36C, DW F/DF41-D, DW F/DF41-F,
DW F/DF41-GO, DW F-36DR,FR,FL,DL,-3,DW F-
31D,DW F-31GO ,DW F-36ST,036,B41-HC
Prew ay
Models DW 36, DW 36A, DL36DW , DW 42, FF42,
DL42DW , BE48, PB48, FF48, BE41, FF41, BE41ST,
B142D, FF36, B136SEM, DL360A5, BE41SEM, B136D-
3M, B136D, DL36DOA, PB4250, DL36D, SL36PB
M artin
Models BC3642, BC3642M, BB3642, BB3642C,
A39, AC39, A33, AC33, A/AC36, A42, AC42, DBB36,
DBC36, BW 36B, BW 42B, B-36, C-36, C-36M, DBB361,
DBC361, M42, M36, BB4250, BB4250C, BC4250,
BW 4245A, LF36B
Superior
Models SP38C-1, RD-3300, RD-3800, RD-
4300, RC-3310, RC-3310, PC-3310, PC-3810, RC-4310,
HC 3320, HC-3820, HC-4320, HCE-3550, HCE-4050,
HCE-4550, CF-3860, and Hearthstar Fireplace 33A, 33B,
38A,38B,43A,43B,35B-N,38H, 40B-N, 45B-N, 3800 Series
Tem co
Models 36-5, TBF42-2RSA, EE36-1
Your ZCF m ust be sound and in good operating condition.
The chim ney should be cleaned before installation if
necessary. Inspection by a local building official, fire
m arshal, certified chim ney sweep, or other qualified
personnel is recom m ended.
Your ZCF MUST have been installed in accordance with
the m anufacturer’s specifications and to all local building
codes.
Installation:
1. Check your fireplace dim ensions - 25" wide in front, 20"
wide in back, 18" deep and 19" high. (See figure 1)
2. The fireplace’s ash lip, sm oke shelf, sm oke baffle, and
firebrick m ay be rem oved if necessary. The dam per
m ust be rem oved.
3. Check proper clearance to com bustibles as shown in
Figures 2 and 3.