WA_DEV_W228_PTS_002 Rev
001
Page 74 of 108
Product Technical Specification &
Customer Design Guidelines
The
voltage
of
this
signal
has
to
be
pulled
LOW
for
at
least
685ms
for
powering
ON.
Within
this
685ms,
the
WISMO_READY
signal
will
initially
set
to
HIGH
for
about
135ms
and
then
resume
to
LOW.
During
the
power
ON
sequence,
an
internal
reset
is
automatically
performed
for
38ms
(typically).
During
this
phase,
any
external
reset
should
be
avoided.
Once
the
WISMO228
is
properly
powered
ON,
the
WISMO_READY
pin
will
set
to
HIGH
level
to
acknowledge
the
successful
powering
ON
of
the
WISMO228
before
it
is
ready
to
operate.
The
ON/~OFF
signal
can
be
left
at
LOW
level
until
power
off.
The
recommended
way
to
release
the
ON/~OFF
signal
is
to
detect
the
WISMO_READY
signal
within
685ms
of
powering
ON
while
the
level
pulse
of
the
ON/~OFF
signal
is
set
to
LOW,
and
wait
until
the
WISMO_READY
signal
goes
HIGH
again.
Power OFF
The
WISMO228
can
be
powered
off
by
either
software
or
hardware.
Refer
to
the
following
diagram
for
the
power
OFF
sequence.
Figure 36. Power-OFF Sequence
Содержание WISMO228