2: Power Interface
Power supply
The host device must provide power to the AirPrime soldered-down
module over pins 42 and 44 (VCC_3V6) as detailed in
Table 2-1
.
Note: The host must provide safe and continuous power to the module; the
module does NOT have protection circuits to guard against electrical
overstress.
Electrostatic discharge (ESD)
The host device must provide adequate ESD protection on digital
circuits and antenna ports as detailed in
Table 2-2
.
Note: The level of protection required depends on your application.
Table 2-1: Power supply requirements
Requirement type
Value
Power supply
3.6 V (nominal)
Voltage range (V
min
–V
max
)
3.3–4.3 V
Current (instantaneous (
≤
5 ms) 3 A
Current (continuous)
700 mA
Table 2-2: ESD specifications
Category
Connection
Specification
Operational
RF port (antenna launch
and RF connector)
•
IEC-61000-4-2—Level (Electrostatic
Discharge Immunity Test)
Non-operational Host connector interface
Unless otherwise specified:
•
JESD22-A114-B +/- 2kV Human Body Model
•
JESD22-C101 +/- 300V Charged Device
Model
Signals
USIM connector
ESD protection is highly recommended at the
point where the USIM contacts are exposed, and
for any other signals that would be subjected to
ESD by the user.
Other host signals
Содержание AirPrime SL8080
Страница 1: ...AirPrime SL8080 Hardware Integration Guide 2400058 Rev 0 1 Draft A ...
Страница 2: ......
Страница 6: ...AirPrime SL8080 Series Hardware Integration Guide 6 Proprietary and Confidential 2400058 ...
Страница 8: ...AirPrime SL8080 Series Hardware Integration Guide 8 Proprietary and Confidential 2400058 ...
Страница 14: ...AirPrime SL8080 Series Hardware Integration Guide 14 Proprietary and Confidential 2400058 ...
Страница 21: ......
Страница 22: ......