Introduction to the AirLink RV55
Rev. 1 June 2019
11
41113042
Router Configuration and Management
You can configure and manage your RV55 router using:
•
ACEmanager
—a browser-based router management application
Refer to the ALEOS Software Configuration User Guide available for download at
.
•
AirLink Management Service (ALMS)
—a cloud-based router management service
provided by Sierra Wireless
For more information, visit
or contact your Sierra Wire-
less distributor.
•
AirLink Mobility Manager (AMM)
—a Network Management solution that provides a
consolidated view of the entire vehicle fleet and enables simplified management,
control and monitoring of connected AirLink routers.
•
AT Commands
For a complete list of AT Commands, refer to the ALEOS Software Configuration User
Guide.
Power Modes
The AirLink RV55 router has three power modes:
•
On—The CPU and the radio are on. The current draw is 900 mW (75 mA @ 12 VDC)
when the router is idle (i.e. no traffic is being sent or received).
•
Standby—The CPU and the radio are off, but can be woken by an I/O input or at a
configured time. Current draw is 53 mW (4.4 mA @ 12 VDC).
•
Off—All power is switched off. Ignition is low, but Vin remains connected. Current
draw is 5 mW (400 µA @ 12 VDC).