4116298
Rev 7.0
November 07, 2016
43
Product Technical Specification and
User Guide
Reliability Compliance and
Recommendations
7.2.5.
Mechanical Resistance Stress Tests
The following tests the modem
’s resistance to vibrations and mechanical shocks.
Table 28.
Mechanical Resistance Stress Tests
Designation
Condition
Sinusoidal Vibration Test
SVT
Standard: IEC 60068-2-6, Test Fc
Special conditions:
Frequency range: 16Hz to 1000Hz
Displacement: ±0.35mm (peak-peak)
Frequency range: 16Hz to 62Hz
Acceleration: 5G
Frequency range: 62Hz to 200Hz
Acceleration: 3G
Frequency range: 200Hz to 1000Hz
Acceleration: 1G
Sweep rate: 1 octave/min
Test duration: 20 cycles
Sweep directions: X, Y and Z
Operating conditions: Un-powered
Duration: 48 hours
Random Vibration Test
RVT
Standard: IEC 60068-2-64
Special conditions:
Frequency range:
0.1 g2/Hz at 10Hz
0.01 g2/Hz at 250Hz
0.005 g2/Hz at 1000Hz
0.005 g2/Hz at 2000Hz
Peak factor: 3
Duration per axis: 1 hr
Number of axis: 3 (X, Y and Z)
Operating conditions: Un-powered
Duration: 24 hours
Mechanical Shock Test
MST
Standard: IEC 60068-2-27, Test Ea
Special conditions:
Shock Test 1:
Wave form: Half Sine
Peak acceleration: 30G
Duration: 11ms
Number of shocks: 8 per direction
Number of directions: 6 (±X, ±Y, ±Z)
Shock Test 2:
Wave form: Half Sine
Peak acceleration: 100G
Duration: 6ms
Number of shocks: 3 per direction
Number of directions: 6 (±X, ±Y, ±Z)
Operating conditions: Un-powered
Duration: 72 hours