WA_DEV_FEX20_UGD_002
Rev 002
April 26, 2010
115
Fastrack Xtend User Guide
Reliability Standards: Compliance and
Recommendations
16.3.2.4. Thermal Resistance Cycle Stress Test
The following tests the Fastrack Xtend
‟
s resistance to extreme temperature cycling.
Table 84: Thermal Resistance Cycle Stress Tests
Designation
Condition
Thermal Shock Test
TSKT
Standard: IEC 60068-2-14
Special conditions:
Upper temperature: +90°C
Lower temperature: -40°C
Rate of temperature change: 30s
Number of cycles: 200
Duration of exposure: 30 minutes
Recovery time: 3 hours
Operating conditions: Un-powered
Duration: 72 hours
16.3.2.5. Mechanical Resistance Stress Tests
The following tests the Fastrack Xtend
‟
s resistance to vibrations and mechanical shocks.
Table 85: Mechanical Resistance Stress Tests
Designation
Condition
Sinusoidal Vibration Test
SVT1
Standard: IEC 60068-2-6, Test Fc
Special conditions:
Frequency range: 10Hz to 1000Hz
Displacement: ±5mm (peak)
Frequency range: 16Hz to 62Hz
Acceleration: 5G
Frequency range: 62Hz to 200Hz
Acceleration: 3G
Frequency range: 200Hz to 1000Hz
Acceleration: 1G
Sweep rate: 1 oct/min.
Test duration: 20 cycles
Sweep directions: X, Y and Z
Operating conditions: Un-powered
Duration: 72 hours
Random Vibration Test
Standard: IEC 60068-2-64