Sierra Video
49
Installation
Introduction
The Sm-xx 1U frame may be installed in 19 inch bays with 426mm depth (~450mm
including connectors). Ventilation is produced in each frame with exhaust fans on the left
hand side (viewed from front) and intake grilles at the right. Frames should be installed
into bays such that airflow through these apertures is not impeded.
Note:
The front rack ears are intended to provide a means of retaining the unit in the
rack.
To ensure adequate support the unit must also be supported at the rear of
the frame.
Please
ensure that ventilation is not impaired when selecting suitable
supports.
Power and Fuses
The mains voltage (240/100 volts) will be auto detected provided it is in the range 90 –
240 V and 47 – 63Hz. A 5A fuse is fitted and a spare fuse should be located under the
pull-out flap.