Sierra Flame BONAPARTE-36 Скачать руководство пользователя страница 1

Page 1 of 44   

CLIENT # LC773211 

 

BONAPARTE 36 BUILDER’S LINEAR 

               16,000 BTU

 

 

 

Natural Gas & Propane 

Installation and Operating Instructions 

 

MODEL: BONAPARTE-36 

         (P4 certified at 55.8% for NG) 

 

 

 

 

 

 

 

 

 

WARNING 

IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR 

EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or 

any other appliance. 

WHAT TO DO IF YOU SMELL GAS: 

 

Do not try to light any appliance 

 

Do not touch any electrical switch; do not use any phone in your building 

 

Immediately call your gas supplier from a neighbour’s phone. Follow gas supplier’s 

instructions 

 

If you cannot reach your gas supplier, call the fire department. 

Installation and service must be performed by a qualified installer, service agency or gas 

supplier. 

WARNING: Improper installation, adjustment, alteration, services or maintenance can cause 

injury or property damage. Refer to this manual. For assistance or additional information 

consult a qualified installer, service agency or the gas supplier. 

INSTALLER: Leave this manual with the appliance. 

 

CONSUMER: Retain this manual for future reference.

 

PLEASE READ THIS MANUAL BEFORE 

INSTALLING OR USING THIS APPLIANCE.  

SAVE THIS MANUAL FOR FUTURE 

REFERENCE. 

A BARRIER DESIGNED TO REDUCE THE RISK OF 

BURNS FROM THE HOT VIEWING GLASS IS 

PROVIDED WITH THIS APPLIANCE AND SHALL BE 

INSTALLED.

 

Содержание BONAPARTE-36

Страница 1: ...as supplier from a neighbour s phone Follow gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified install...

Страница 2: ...ous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournis...

Страница 3: ...rmostat Wall Switch or Digital On Off Remote 16 3 3 4 Direct Vent Information 16 22 3 3 5 Glass Rock Media Installation 23 3 3 6 Door Installation and Safety Screen 23 25 3 3 7 Initial Firing 26 3 3 8...

Страница 4: ...s et intoxication au monoxyde de carbone DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZA...

Страница 5: ...reil doit tre remplac avant de faire fonctionner l appareil Installation et r paration doit tre effectu e par un technicien qualifi L appareil doit tre inspect avant son utilisation et au moins annuel...

Страница 6: ...a GAS INLET SUPPLY PRESSURE ENTREE DE PRESSION Minimum 5 0 w c 1 2 kPa Minimum 7 0 w c 1 74 kPa Maximum 10 5 w c 2 61 kPa Maximum 13 0 w c 3 23 kPa ORIFICE SIZE 0 4500 FORMAT D ORIFICE 48 DMS 56 DMS A...

Страница 7: ...nsed gas fitter Failure to comply will void the warranty This appliance has been certified for use with natural gas This appliance is not for use with solid fuels CODES D INSTALLATION Cet appareil est...

Страница 8: ...e de combustion Maintain adequate accessibility clearances for servicing and proper operation Respecter les distances minimales d accessibilit suffisante pour l entretien et bon This appliance shall n...

Страница 9: ...toddlers young children and at risk individuals out of the room and away from hot surfaces Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the applia...

Страница 10: ...y call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety...

Страница 11: ...par un technician qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau INSTRUCTIONS D ALLUMAGE 1 ARR TEZ Lisez les instructions de s curit sur la por...

Страница 12: ...witch operates Variable Speed Setting Turn the control to the desired setting When the knob is turned fully clockwise the fan will set to minimum speed Warning Electrical Grounding Instructions This a...

Страница 13: ...s components as this will damage the valve Ne pas communiquer 120 VAC la valve de contr le du gaz ou de ses composantes car cela endommagerait la vanne 3 2 UNPACKING Please check the appliance careful...

Страница 14: ...sur cette page illustre les dimensions et les emplacements admissibles chemin e L angle de 45 degr s peut tre utilis pour d terminer la taille permise manteau repose sur l l vation au dessus de la gar...

Страница 15: ...ppliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or le...

Страница 16: ...FORMATION The unit must be connected to listed 2 ply aluminium venting 4 flex vent on the exhaust side and listed 6 flex vent on the air intake side Install the vent components according to the manufa...

Страница 17: ...ge Figure 4 This appliance s venting system is room sealed or Direct Vent This means that it does not require room air for combustion but draws air from outside the building USE OF COUPLERS WITH FLEX...

Страница 18: ...al termination cap part 1393 Note 2 Ply Horizontal venting shall be supported by means of a steel strap every 3 Example Where A A Vertical 2 And B B Horizontal 5 EXAMPLES MINIMUM VERTICAL V1 V2 MAXIMU...

Страница 19: ...llow above instructions for resealing venting when reconnecting to system FIGURE 6 VENT RESTRICTOR INSTALLATION VENT RESTRICTOR To fasten the Restrictor Plate to the ceiling of the firebox 1 Remove th...

Страница 20: ...enter mark inside dimensions Cut and frame the exterior wall to accept the wall thimble Install the wall thimble on the inside of the exterior wall shield using wood screws Attach the venting to the t...

Страница 21: ...t ceiling install a Box Wall thimble Cut a 9 square hole and frame as shown in the diagram below NOTE ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING CLEARANCES ETC MAY VARY FROM STATE TO STAT...

Страница 22: ...da 12 in 30 cm porch deck or balcony 0 0 3 3 1 In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Ga...

Страница 23: ...orte Turn your fireplace on and wait approximately 10 15 minutes until the flames are a nice yellow colour Note the flame pattern and in any low or high areas adjust the amount of river glass to corre...

Страница 24: ...top of the door bracket and seal the door onto the fireplace Quand il est ferm correctement le loquet se brancher sur le dessus du support de porte et sceller la porte sur la chemin e Removal is in re...

Страница 25: ...s dans une goutte de silicone haute temp rature dans chacune des quatre coins du cadre de porte et avec le bord arrondi face dans le lieu porte le panneau de verre de nouveau dans le cadre de la porte...

Страница 26: ...arm up Parfois apr s un d marrage froid la vapeur peut se condenser et voiler le verre et les flammes peuvent tre partiellement bleu Apr s quelques minutes l humidit dispara t et les flammes deviendro...

Страница 27: ...unit at higher elevations it is necessary to decrease the input rating by replacing the existing burner orifice with a smaller size for installations over 4500 feet 1372m For the USA de rate the unit...

Страница 28: ...ttom of the firebox before pulling the fan out through the gap on the right hand front of the unit Une fois que le ventilateur est d tach du mur retirez l aimant de l extr mit moteur du ventilateur Re...

Страница 29: ...1 Remove the door as in 3 3 6 Enlevez la porte comme dans 3 3 6 2 Undo the thumb screws on the valve mount brackets at either end of the valve and slide valve out through access area below door Desse...

Страница 30: ...E RECOMMAND 1 The venting system should be annually inspected by a qualified agency Le syst me de ventilation devrait tre inspect s annuellement par une agence qualifi e 2 Visually check the burner an...

Страница 31: ...ce or tubing When the appliance is back in service check the pilot flame pattern For re lighting refer to the lighting instructions in Section 2 1 Un nettoyage p riodique est n cessaire pour un foncti...

Страница 32: ...la vanne de gaz 7 Disconnect the thermostat or on off switch wires from the valve if applicable D branchez le thermostat ou marche arr t fils de l interrupteur de la vanne si applicable 8 Remove the g...

Страница 33: ...ay lit after following the lighting instructions A Thermocouple Valve 1 Weak or improperly located pilot flame 1 Adjust and clean pilot The flame must impinge on or engulf the thermocouple as shown in...

Страница 34: ...anual for correct log placement V Flame burns blue and lifts off burner 1 Insufficient combustion air being supplied 1 Ensure that no foreign material blocks air inlets Ensure the vent is adequate 2 M...

Страница 35: ...estrictor 2543 N A Door Glass Gasket 6AL N A Orifice NG MP0505 48 N A Orifice LP MP0505 56 N A Glass Kit BGK N A Fan GL43X188 UR Intermittent Pilot Remote Control Valve Parts Description Part Pilot As...

Страница 36: ...extended whatsoever by any of our representatives A licensed authorized service technician or contractor must have installed the gas fireplace Installation must be done in accordance with the installa...

Страница 37: ...laim 7 0 GARANTIEDEPROTECTION Les produits Inca Metal Cutting sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s fiers de leur travail Le br leu...

Страница 38: ...a discr tion se d charger de toutes les obligations relatives cette garantie en remboursant l acheteur original garanti le prix de gros de toutes les pi ces garanties mais d fectueuses Nonobstant les...

Страница 39: ...Page 39 of 44 8 0 LABEL INFORMATION...

Страница 40: ...remove the grounding prong from this plug AVERTISSEMENT Instructions la terre lectrique Cet appareil est quip d un trois broches terre pour votre protection contre les risques de choc lectrique et do...

Страница 41: ...Page 41 of 44 APPENDIX A AMERICAN FLAME VALVE INFORMATION Copper wire...

Страница 42: ...Page 42 of 44 APPENDIX A Continued...

Страница 43: ...is in the ON position and the appliance ON OFF switch is turned on the pilot will spark and light When the appliance ON OFF switch is turned to OFF the pilot will stay ON when the main burner shuts o...

Страница 44: ...Page 44 of 44 APPENDIX A Continued AF 4000 Wiring Diagram Inca Metal Cutting Ltd Unit 100 11091 Bridgeport Road Richmond BC V6X 1T3 Canada Brown...