Page 16 of 54
3.3.1 MINIMUM CLEARANCES / DÉGAGEMENTS
NON-COMBUSTIBLE BOARD – 12
"
(305mm) x 64.25
"
(1632mm) WILL BE
SUPPLIED BY MANUFACTURER AND MUST BE ATTACHED TO TOP OF FIREPLACE
SEE DIAGRAM PAGE 18
MINIMUM CLEARANCES TO COMBUSTIBLES
A = 58”
TO INTERNAL CEILING
B = 3.5”
TO INTERNAL BACK COMBUSTIBLES
C = 17.5”
TO BACK WALL FROM FRONT OF UNIT
D = 6”
FROM EDGE OF FIREPLACE TO SIDE WALL
E = 39”
FROM BOTTOM OF FIREPLACE TO STEEL STUD
F = 2”
TO INTERNAL SIDE COMBUSTIBLES
G=45”
MINIMUM FROM BOTTOM OF FIREPLACE TO MANTLE
(SEE DIAGRAM NEXT PAGE)
0”
BASE OF UNIT TO FLOOR
A
B
C
D
E
F
G
58
.0
0
Содержание AUSTIN-65G-LP-DELUXE
Страница 25: ...Page 25 of 54 34 20 A A B B Example Where A A Vertical 2 And B B Horizontal 5 15 MINIMUM 15 MAXIMUM ...
Страница 47: ...Page 47 of 54 8 0 LABEL INFORMATION ...
Страница 49: ...Page 49 of 54 APPENDIX A AMERICAN FLAME VALVE INFORMATION ...
Страница 50: ...Page 50 of 54 APPENDIX A Continued ...