background image

Z-PLUG Termination Instructions

2a

Tools

2b

2c

Remove center spline

Prep foil/drain wire,
remove mylar

Flush Cutters

Jacket
Stripper

Z-PLUG
Termination tool
(p/n: Z-TOOL-ZP)

Plug Body

Termination

Module

Boot & Latch
Protector (optional)

!

F/UTP shown here

See back page for other
cable types.

Foil

Invert
Foil

Wrap
Drain
wire

Remove
Mylar Wrap

3

T568A
T568B

Remove
Jacket

~ 2 in. (51
mm)

Optional
Accessories

!

4

1

Good

UTP (skip to step 2C)

F/UTP
(23-26 AWG)

*S/FTP
22 AWG

TIP:

Arrange pairs in line

prior

to insertion

leading with the brown pair along with either
the orange for T568A or green if T568B.

Not
Good

*OSP
F/UTP 23 AWG

Foil over
inner jacket.

*Other cable preparation recommendations and
supplemental instructions are available for these and other
cable types. See back page for additional details.

End of
outer
jacket.

Tip for 22 AWG
S/FTP: Wrap
braid on top of
foil pairs in
direction of door.

Braid wrap
direction

Aramid yarn

Arrange pairs and
insert into module.
(see tip above prior
to insertion).

If pair
crossing, keep
close to jacket

If pair crossing is
necessary, this should be
done before next step.

0

-

5

m

m

(0

.2

in

.)

End of
Jacket

8 7 4 5 < Pin#’s > 2 1 6 3

Содержание Z-PLUG

Страница 1: ...rs in line prior to insertion leading with the brown pair along with either the orange for T568A or green if T568B Not Good OSP F UTP 23 AWG Foil over inner jacket Other cable preparation recommendations and supplemental instructions are available for these and other cable types See back page for additional details End of outer jacket Tip for 22 AWG S FTP Wrap braid on top of foil pairs in directi...

Страница 2: ...tion Align termination module latch blue brown side with plug latch Plug Latch Flush Cutters only Trim flush 0 1 mm 0 04 in Optional For large O D cables pliers may be helpful when lacing Click Tip for larger OD cables Press to seat before closing door Press Door Insert onto matching shape with door side up 2 1 Remove excess shield to prevent interference when attaching boot foil braid OR 2 ...

Страница 3: ... R2 Use underside of tool handle to defeat termination module latch Unassembling for re termination R1 Remove boot by disengaging latches can use small screwdriver if necessary Boot Removal Removal Tools Flat Screwdriver Z PLUG Tool Probe Pic Optional Press Pull 1 2 Press 1 Remove laced conductors Probe pic use optional Open door using small screwdriver R2 PRESS 2 1 PRESS 1 2 Plug Pin Positions ...

Страница 4: ...dans un endroit humide D Ne jamais installer pendant un orage To ensure you have the latest revision to this document please visit Z PLUG Termination Alternate Cable types S FTP Stranded 26 AWG Continue To Step 3 4X Foil 2a 2b 2c 2d 2e 38 mm 1 5 in 13 mm 0 5 in 13 mm 0 5 in Continue To Step 3 U FTP Solid 2a 2b 70 mm 2 75 in 6 35 mm 25 in 1X foil Drain Wire 3X foil 360 2X Note for OSP Category 6A s...

Отзывы: