Interconnection
Direct Connection
2-Wire Extension
Coaxial Extension
Note:
When connecting to a SITRANS LUT400, a SITRANS LUC500, a MultiRanger 100/
200, or a HydroRanger 200, the white, black, and shield wires are all connected separately.
DO NOT tie the white and shield wires together.
Note:
When connecting to a SITRANS LUT400, a SITRANS LUC500, a MultiRanger 100/
200, or a HydroRanger 200, the white, black, and shield wires are all connected separately.
DO NOT tie the white and shield wires together.
Note:
Grounding transducer as shown is mandatory per safety regulations and for
isolation against electrical interference.
wht/shld
blk/hot
blk
wht
Siemens Milltronics controller (typical)
junction
box
blk
drain/shield
wht
extend cable using 18 AWG shielded/twisted pair
extend cable using RG - 62 A/U coax for optimum
signal to noise ratio