![Siemens WAC 11 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/siemens/wac-11/wac-11_installation-instructions_384239002.webp)
Fig. 4
Fig. 5a
Fig. 5b
Fig. 5c
WAC 12
WAC/WAS 11
WAS 11
Audio to
other
WAS 11
e.g. WMA 11
WAC 11
WAC 12
WMA 11
WAC 11
WAC 11
WAC 11
WAC 11
Fig. 5d
3.4 Mounting (Fig. 4)
- The housing can be mounted flat or at 45
o
.
- Always use two attaching points which are one above the
other, including for corner mounting.
4. Wiring
4.1 Audio (Fig. 5)
To avoid side-tone, a twisted core pair at least 0.6 mm in dia. must
be used. The audio connection to the central control unit must
not be more than 200 m long. The audio output depends on the
cable length and core cross-section. The audio output (A- and
A+) of the WAC 11 is connected to the audio input (AE- and AE+)
of the WAC 12, which acts as a master (Fig. 5a).
Alternatively, the audio output (A- and A+) of the WAC 11 can be
directly connected to the audio input (A- and A+) of the central
control unit (e.g. WMA 11) (Fig. 5b). Where several WAC 11 are
used, all WAC 11 must be connected directly to the WAC 12 (Fig. 5c) or
to the central control unit (Fig. 5d) to obtain optimum performance.
4.2 Tamper (Fig. 5a)
The tamper outputs (T,T) of the WAC 11 and WAS 11 are connected
in series to the tamper inputs (T- and T+) of the WAC 12.
5. Start-up
5.1 Microphone sensitivity
The sensitivity of the microphone must be matched to the room
and ambient noises (potentiometer
T
, Fig. 3).
Where sensitivity is reduced, the reception of quiet signals
naturally reduces. The following ranges are normally obtained.
- Approx. 3.5 m with potentiometer on min.
- Approx. 6.5 m with potentiometer on mid position.
- Approx. 8.5 m with potentiometer on max.
5.2 Speaker
Set the required volume using potentiometer (
Q
, Fig. 3).
5.3 "Microphone active"LED
- Switch (
E
, Fig. 3) open: LED active.
- Switch (
E
, Fig. 3) closed: LED inactive.
6. Close housing
1 - Engage cover at the top in the openings in the base of the
housing.
2 - Close the cover by pushing downwards until the locking
tab engages.
7. Technical data
Supply Through
audio
Power consumption, quiescent state
0 mA
Power consumption, "challenge" state
7 mA
Operating temperature
-10°C to +55°C
Housing material
ABS
Dimension in mm
H 145 x B 105 x T 70
Safety class
IP 30
Weight 230g
The right to make technical changes to the described equipment without prior notice is
reserved.
T+
T-
AE+
AE-
T
T
A- A+
NC
T
T
A- A+
A+
A-
A+
A-
A+
A+
A-
A-
AE+
AE-
A+
A+
A-
A-
A+
A-