2   Introduction

2.5

Wirings

Basically all wiring are performed according to each of the system's documentation.

The only special wiring is the RS485 cabling between the SR35iA Aperio Controller

and the Aperio™ hubs.

Each SR35iA Aperio Controller can connect to maximum 15 hubs on the RS485 bus.

Note that the RS485 bus must be terminated in each end and this is done by setting

a DIP switch in the actual hub.

7

Siemens AB

2015-05-05

Security Products

Содержание SR35iA series

Страница 1: ...Access Control SR35iA Aperio Controller Configuration Manual MP1 Siemens AB Security Products ...

Страница 2: ...ubject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Document nr A 100162 1 ...

Страница 3: ... 4 System overview 6 2 5 Wirings 7 3 Configuration 8 3 1 Aperio configuration 8 3 2 Bewator Entro configuration 8 3 2 1 SR35iA Aperio Controller setup 9 3 2 2 Bewator Entro card parameters 9 3 2 3 Configure doors 9 3 3 Omnis configuration 10 3 3 1 Omnis special notes when using Aperio doors 10 3 3 2 Omnis functions not supported with Aperio 11 ...

Страница 4: ...d together with ASSA ABLOY Aperio door solutions and the Omnis Security system More information can be obtained from the separate reference manuals supplied with each of the systems l ASSA ABLOY Aperio l Bewator Entro l Omnis Different information might be useful dependent of which system you are familiar with 4 Siemens AB 2015 05 05 Security Products ...

Страница 5: ...s applies when using the Aperio together with Bewator Entro and Omnis Maximum number of Aperio hubs per SR35iA Aperio Controller 15 hubs Maximum number of Aperio readers doors per Aperio hub 8 readers doors Recommended by ASSA is 4 Maximum number of doors per SR35iA Aperio Controller regardless of number of hubs SR35iA 8 SR35iA 16 SR35iA 32 8 16 32 Maximum RS485 cable length 1200 m Maximum distanc...

Страница 6: ...ault This means that a command to unlock or lock the door may become effective a time between 0 60 minutes Version 3 With this version of the Aperio lock it will contact the hub at least every ten seconds Any commands for unlocking or locking will take effect much quicker 2 4 System overview Following picture shows the system layers Note that three different system concept co operate Omnis Bewator...

Страница 7: ...cial wiring is the RS485 cabling between the SR35iA Aperio Controller and the Aperio hubs Each SR35iA Aperio Controller can connect to maximum 15 hubs on the RS485 bus Note that the RS485 bus must be terminated in each end and this is done by setting a DIP switch in the actual hub 7 Siemens AB 2015 05 05 Security Products ...

Страница 8: ... Entro and Omnis Note 2 Maximum number of Access group Personal doors must not exceed six 6 3 1 Aperio configuration All setup have to be done according to the original Aperio documentation and using the Aperio PAP Configuration tool The addressing of the hubs is done via DIP switches The hubs communicates via RS485 to Bewator Entro and wireless to the locks 3 2 Bewator Entro configuration The SR3...

Страница 9: ... on with Username and Password 2 Select on the menu System System settings 3 Click the Card reader parameters tab 4 Click on Custom and enter Start position as 1 and Number of digits as 16 5 Click OK and close the dialog box 3 2 3 Configure doors When the Aperio hubs are connected the doors can be renamed and setup referring to the ordinary Bewator Entro manuals You see new doors as CnHyyAxxx wher...

Страница 10: ...orm in Omnis is 8 and for Bewator Entro it is 6 If user enters 8 Access groups Personal door the last two is not entered into Bewator Entro and will not work Maximum number of Access group Personal door is 6 for Omnis with Aperio Access Group The Access group is created and edited in Bewator Entro which door to access and when Shown in Omnis as name and not possible to edit In Omnis it is possible...

Страница 11: ... Aperio readers in Omnis Graphics Not possible for graphic status indication of Aperio doors Alarm control Not possible to have Aperio readers in alarm zones Anti passback Not possible to have global anti passback with Aperio door Personal code No personal code instead of cards can be used 11 Siemens AB 2015 05 05 Security Products ...

Страница 12: ...rnational Headquarter Englundavägen 7 SE 171 24 Solna Tel 46 8 629 0300 www siemens com securityproducts 2015 Copyright by Siemens AB Data and design subject to change without notice Supply subject to availability Document Nr A 100162 1 Edition Date 2015 05 05 ...

Отзывы: