Technical Data 

17 

Siemens Building Technologies

 

 

Fire Safety & Security Products 

 

09.2008

 

 

(Grade 3) EN50131-6:2008 (Grade 3) 

1)

 For EN compliance the supplied current needs to be supported by the battery for required stand by time 

2)

 Max. 400m between devices with cable types IYSTY 2 x 2 x Ø 0,6 mm (min.), UTP cat5 (solid core) or Belden  9829 

3.2 Keypad 

 

LC-display 

2 x 16 characters 

Special function keys 

Multi dimensional navigation key and 2 soft keys 

Status LEDs 

Card reader 

SPCK421: 125 kHz, EM 4102 or compatible (e.g. SiPASS) 

Card read distance 

SPCK421: 10 mm 

Operating voltage 

9.5 – 14 V DC 

Current consumption 2) 

SPCK420: Min: 60 mA at 12 V DC,  Max. 70 mA at 12 V DC 

SPCK421: Min. 90 mA at 12 V DC, Max. 110 mA at 12 V DC 

Field bus 3) 

X-BUS on RS-485 (307 kb/s) 

Tamper contact 

Front/rear spring tamper 

Operating temperature 

5 - 40 °C 

Relative humidity 

Max. 90 % (no condensation) 

Housing protection 

IP30 

Housing protection class 

Class II Indoor General 

Housing material 

ABS 

Colour RAL 

9003 

Mounting 

Surface, wall-mounted, height of 1.30 - 1-50 m 

Standards 

Designed to meet  

EN50131-1:2006 (Grade 3),  

TS50131-3:2003 (Grade 3) 