Command lists
10.3 Command groups of the SIWAREX WP231
SIWAREX WP231
144
Manual, 07/2014, A5E31238908A-02
10.3
Command groups of the SIWAREX WP231
The following commands can be triggered in the scale data block DB_SCALE in the area
CMD1 to CMD3:
Table 10- 6 Command groups of the SIWAREX WP231
Command group
Description
1 ... 99
Commands are forwarded from the function block via data record DR 2 to the module (scale
commands, weighing commands, log commands). The meanings of the commands corre-
spond to the command list (see →
2000 + X
Reading of a data record, X corresponds to the data record number.
Example: Data record 3 transmitted by SIWAREX module to SIMATIC CPU → 2000
+ 3 =
command code 2003
4000 + X
Writing of a data record, X corresponds to the data record number.
Examp
le: Data record 3 transmitted by SIMATIC CPU to the SIWAREX module → 4000
+ 3 =
command code 4003
7001
Read all data - Read all data from the SIWAREX to the CPU
7002
Write all data - Write all data from the CPU to the SIWAREX (service mode has to be turned
on)
Additional information on transmission of commands from the control program by means of
the SIMATIC interface is available in chapter Integration in SIMATIC S7-1200 (Page 145).
Содержание SIWAREX WP231
Страница 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Страница 24: ...Application planning 4 2 Parameter assignment options SIWAREX WP231 24 Manual 07 2014 A5E31238908A 02 ...
Страница 108: ...Scale parameters and functions 8 15 DR 15 tare settings SIWAREX WP231 108 Manual 07 2014 A5E31238908A 02 ...
Страница 131: ...Scale parameters and functions 8 26 DR 48 date and time 2 for Modbus SIWAREX WP231 Manual 07 2014 A5E31238908A 02 131 ...
Страница 132: ......
Страница 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Страница 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Страница 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...