Weighing Functions
SIWAREX FTA
5-100
Name
Type
Address
Default
Range of Values / Explanation
Reference
98
Table 5-16
DR 23 Allocation
5.16.1 DR 23 - Text Selection for automatic logging
For automatic logging of weighing results, a message text consisting of 4
predefined text blocks can be selected by the user. These text blocks are defined
in DR 40 to DR 43. (see
5.16.2 DR 23 - Max. single set weight
The set value for an individual weighing procedure is checked with this definition.
5.16.3 DR 23 - Inhibition time - Coarse
After coarse signal activation, the scale can start to oscillate, causing significant
deviations in measurement values in the scale's switch-off points. If the evaluation
of the weight value is not expedient during these oscillations, the coarse inhibition
time can be defined. The coarse inhibition time is activated together with the
coarse signal, and weight determination is blocked for the duration of the defined
inhibition time, meaning the measurement failure (operating error 17) is eliminated.
This prevents the coarse signal from switching off prematurely.
5.16.4 DR 23 - Fine Inhibition time
After switching the coarse signal off, dosing continues with the fine signal. The fine
inhibition time can be set if scale oscillation could switch off the fine signal
prematurely. The fine inhibition time is activated when the course signal is switched
off, and weight determination is blocked for the duration of the defined inhibition
time, meaning the measurement failure (operating error 17) is eliminated.
5.16.5 DR 23 - Inhibition time Set-Act comparison
After the inhibition time is started with command 111, the current weight is not
monitored during the defined period, meaning the measurement failure (operating
error 17) is eliminated.
Dosing can be started during the inhibition time. The inhibition time also lasts until
after the dosing is complete. If dosing is stopped, the inhibition time is also
interrupted.
While the inhibition time is running, it can be restarted with command 111,
extending the inhibition time accordingly.
The function is deactivated when the configured inhibition time elapses or with
command 112.
This function is useful when using discharge aids.
Содержание SIWAREX FTA
Страница 1: ...SIWAREX FTA Device Manual Status 05 2017 ...