english
SITRANS I100
13
Operating instruction A5E02591611-02
5 Engineering
5.1 Max. ambient temperatures
The SITRANS I100 isolators can be used over a wide temperature range. Depending on
the isolator version and installation method different maximum ambient temperatures may
result.
Ventilation:
without ventilation
Installation:
Single unit
DIN-rail
Orientation:
any
vertical
horizontal
Type:
SITRANS I100
70 °C
60 °C
65 °C
Ventilation:
with ventilation
Installation:
Single unit
DIN-rail
Orientation:
any
vertical
horizontal
Type:
SITRANS I100
70 °C
70 °C
70 °C
5.2 Power dissipation
Data sheets are describing the maximum power dissipation in standard operation (output
20 mA; power supply 24 V DC; load = 250
Ω
). In practice not all isolators are working with
full load. Therefore engineering is done typically with an average power dissipation of 70 %
(P
70%
).
Type
max. power dissipation
70 % power dissipation
SITRANS I100
1.5 W
1.1 W
Содержание SITRANS I100 7NG4124-0AA00
Страница 20: ...SITRANS I100 20 Operating instruction A5E02591611 02 Control drawing FM ...
Страница 21: ...SITRANS I100 21 Operating instruction A5E02591611 02 Control drawing CSA ...
Страница 22: ......
Страница 23: ......