Configuration / project engineering
9.2 Functions
3TK2826 safety relay
28
Manual, 08/2007, GWA NEB 926 1579-02 DS 02
9.2
Functions
Table 9-1
Factory setting
OFF
Schematic
DIP switch
No.
ON
Without cross-circuit detection
1
With cross-circuit detection
NC contact/NO contact evaluation
2
NC contact/NC contact evaluation
2 x 1-channel
3
1 x 2-channel
Debounce time for sensor inputs ∼ 50 ms
4
Debounce time for sensor inputs ∼ 10 ms
Autostart sensor input
5
Monitored start sensor input
Autostart cascading input
6
Monitored start cascading input
With startup testing
7
Without startup testing
Automatic startup after power failure (not
permissible in conjunction with startup testing)
8
Without automatic startup after power failure
DANGER
Automatic start after power failure
In the case of automatic startup after a power failure, the system starts without actuation of
the start button.
If the system is powered down (e.g. for maintenance work), make sure that a hazardous
state cannot arise as a result of an automatic startup when the power supply is activated
again.
Содержание Sirius 3TK2826
Страница 10: ...Product family 3 1 Order numbers 3TK2826 safety relay 10 Manual 08 2007 GWA NEB 926 1579 02 DS 02 ...
Страница 14: ...Functions 5 1 Functions 3TK2826 safety relay 14 Manual 08 2007 GWA NEB 926 1579 02 DS 02 ...
Страница 54: ...External circuitry 10 3 Output circuit 3TK2826 safety relay 54 Manual 08 2007 GWA NEB 926 1579 02 DS 02 ...
Страница 56: ...Commissioning 11 1 Commissioning 3TK2826 safety relay 56 Manual 08 2007 GWA NEB 926 1579 02 DS 02 ...
Страница 60: ...Technical data 12 2 Dimension drawings 3TK2826 safety relay 60 Manual 08 2007 GWA NEB 926 1579 02 DS 02 ...