Tool management
6.7 Start-up of code carrier
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
271
6.7.5
Example: Data string
Structure of a data string
conversion file: wkonvert.txt
Code carrier
variable
Length in
Bytes
Format
Dialog variable
Item1
10
ASCII
T1 Identifier, $TC_TP2
Item2
2
BCD
T2 Duplo, $TC_TP1
Item3
2
BCD
T4 = (Tet1), T5 = (Tet2), T6 = (Tet3), T7 = (Tet4)
Tool size: left, right, top, bottom, $TC_TP3, 4, 5, 6
Item4
10
ASCII
T8 Location type, text for $TC_TP7
Item5
1
BCD
T3 Number of cutting edges, $P_TOOLND[tnr], tnr = tool
number
Item6
4
BCD
A1 Tool OEM1, $TC_TPC1
Item7
4
BCD
A2 Tool OEM2, $TC_TPC2
Item8
2
BCD
C1 Subtype, type, $TC_DP1
Item9
4
BCD
C5 Geometry length1, $TC_DP3
Item10
4
BCD
C10 Geometry radius1, $TC_DP6
Item11
4
BCD
C14 Wear length 1, $TC_DP12
This conversion file can be used to read in the following data string or conversely to generate
this string when writing:
626F687265725F312020000111116E6F726D616C2020202001D00010E3D000000502
05B00002E3B0000003B000E4562F2F
If working with SINTDC, this string corresponds to the interface between SINTDC and HMI
Advanced.
Description
Dividing this string into individual values:
String
Value
Entry
wkonvert.txt
Data types for dialog variables
626F687265725F312020
"Drill_1"
10 ASCII T1
T1 String Identifier, $TC_TP2
0001
1
2 BCD T2
T2 Integer Duplo, $TC_TP1
1111
1,1,1,1
2 BCD T4=(Tet1),
T5=(Tet2),
T6=(Tet3),
T7=(Tet4))
T4 Integer Tool size: Left
T5 Integer Tool size: Right
T6 Integer Tool size: Top
T7 Integer Tool size: bottom
6E6F726D616C20202020
"Normal"
10 ASCII T8
T8 String Location type, text for $TC_TP7
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...