3 Setting up functions
3.2 Configuring measurements and measurement series
© Siemens AG 2008 All Rights Reserved
ePS Network Services, Function Manual (FH) - Release 08/2008
3-91
Configuring the limit values
With synchronous operation axis test one movement is carried out each forwards
and backwards. The characteristics are calculated separately for each direction. As
standard limit values are defined for the characteristics and are the same for both
directions of movement.
Optionally limit values can be entered which can have different values for both di-
rections for each characteristic.
Fig. 3-11: Measurement series of a synchronous operation axis test on the PC
3.2.3 Universal axis test
Parameter description
Parameters for conducting a universal axis test:
Field Content
Type
Name
Name of the measurement series (meas-
urements do not have a name)
INPUT
Channel
Selection of the required channel: The chan-
nel defines the possible machine axes in the
"Axis" selection list.
SELECTION
Axis
Selection from the possible machine axes
that can be programmed in the selected
channel
SELECTION
Start point
The axis position at which the various
movements of the measurement begin.
The position value is never lower than this
value during measurement.
INPUT