5.4.4
Operating the TCU menu "Modify settings"
"Modify settings for operator panel (TCU)" dialog
The following dialog appears when "Modify settings" is selected from the main menu:
Figure 5-9
TCU menu: Settings
In this dialog, you set the TCU parameters during first commissioning:
● "HT 8 individual mode" (yes/no)
This is only visible with HT 8, and is used to switch between Auto Mode and Individual
Mode.
You do not have to make settings for an HT 8 in Auto Mode because the name is generated
automatically: ("DIP<n>") MCP address and TCU index are derived from the DIP setting
("DIP<n>").
● "Operator panel index - TCU" (0-255)
Defines the TCU index; see column "TCU" on the user interface.
● "Machine control panel address - MCP" (0-255)
Specifies the address of the associated MCP; see column "MCP" on the user interface.
Networking
5.4 Service and diagnostics
TCU 30.3
Manual, 09/2017, A5E40874197
59