Diagnostics
8
8.1
LED displays
LEDs H500 to H505 on the COM board provide information about the following states:
①
H500 - POWER OK (green)
②
H501 - BUSFAULT (red)
③
H502 - BUSSYNC (green)
④
H505: TEMP ALARM (red)
Figure 8-1
MCP 398C - LEDs
Name
State
Meaning
H500
Lit
All internal voltages are in the setpoint range.
Not lit
At least one of the generated voltages has fallen below its setpoint; a
reset will be initiated.
H501
Not lit
No PROFINET communication.
Lit
PROFINET is synchronized (STOP state).
Flashes (0.5 Hz) PROFINET is synchronized (RUN state).
H502
Lit
PROFINET group fault.
H505
Lit
The upper limit temperature (T_Critical) of temperature sensor LM77 has
been exceeded.
8.2
Output functions
Requirements
● The MCP is booting.
● There is no communication yet between the MCP and the control, i.e. all of the key LEDs
are flashing.
● The MCP must be in the IE operating mode. For further information, see Settings of switch
In this state, the output functions described in the following can be sequentially called.
Machine control panel: MCP 398C
Manual, 07/2018, A5E43199783B AB
49
Содержание SINUMERIK 840 sl
Страница 26: ...Description 2 4 Rating plate Machine control panel MCP 398C 26 Manual 07 2018 A5E43199783B AB ...
Страница 34: ...Dimension drawings Machine control panel MCP 398C 34 Manual 07 2018 A5E43199783B AB ...
Страница 51: ...3 4 5 6 Diagnostics 8 2 Output functions Machine control panel MCP 398C Manual 07 2018 A5E43199783B AB 51 ...
Страница 62: ...Technical data 9 3 Recycling and disposal Machine control panel MCP 398C 62 Manual 07 2018 A5E43199783B AB ...
Страница 66: ...Safety symbols Machine control panel MCP 398C 66 Manual 07 2018 A5E43199783B AB ...
Страница 68: ...Index Machine control panel MCP 398C 68 Manual 07 2018 A5E43199783B AB ...