4.9.7
This is how you remove the CU310-2 PN
Overview
The activities that are required when replacing a CU310-2 PN are subsequently described.
If the CU310-2 PN has a hardware defect, then it must be replaced by an identical module.
Preconditions:
● The module is defective and must be replaced.
● The control cabinet is in a no-voltage condition, all of the connectors and cables are labeled.
Removing
Procedure:
1. Switch off the complete system, carefully checked that it is in a no-voltage condition and
lock it out so that it cannot be switched on without the appropriate authorization.
2. Access the control cabinet where the CU310-2 PN is located.
3. Use a multimeter to check that the CU310-2 PN really is in a no-voltage condition.
4. If it has not already been done, label all connectors and cables that lead to the module now.
Only then, can it be ensured that the cables are not interchanged.
5. Withdraw the electronics power supply X124.
6. Withdraw the DRIVE-CLiQ cable X100.
7. Withdraw all other cables, if available.
8. Remove the protective conductor connection of the CU310-2 PN.
Service cases - hardware
4.9 Control Unit CU320-2 PN and CU310-2 PN
Software and hardware
134
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
Содержание SINUMERIK 828D Turning