N2: Emergency stop
11.4 Emergency stop sequence
Basic Functions
820
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
11.4
Emergency stop sequence
After actuation of the emergency stop control element, the emergency stop device must operate in the best
possible way to prevent or minimize the danger.
"In the best possible way" means that the most favorable delay rate can be selected and the correct stop
category (defined in EN 60204) can be determined according to a risk assessment.
Emergency stop sequence in the NC
The predefined (in EN 418) sequence of internal functions implemented to obtain the emergency stop state is as
follows in the control system:
1. Part program execution is interrupted.
All machine axes are braked in the relevant axis-specific parameterized time:
MD36610 $MA_AX_EMERGENCY_STOP_TIME (time of braking ramp in event of errors)
The maximum braking ramp that can be achieved thereby, is defned by the maximum brake current of the
respective drive. The maximum brake current is achieved by setting a setpoint = 0 (fast braking).
2. Reset interface signal:
DB11 DBX6.3 (Mode group ready)
3. Set the interface signal:
DB10 DBX106.1 (Emergency stop active)
4. Alarm 3000 "emergency off" is shown.
5. After the expiry of a paramaterized delay time, the servo enables of machine axes are reset.
The setting of the delay time is programmed in machine data:
MD36620 $MA_SERVO_DISABLE_DELAY_TIME (switchoff delay servo enable)
The following setting rule must be observed: MD36620 ≥ MD36610
6. All machine axes are switched in the follow-up mode within the controller.
The machine axes are no longer in position control during this.
Emergency stop sequence at the machine
The emergency stop sequence on the machine is determined solely by the machine manufacturer.
Attention should be paid to the following points in connection to the sequence on the NC:
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...